Greenhouse gas monitoring is important to ensure climate goals are being achieved. This study unveils the potential of using atmospheric tall towers in direct flux measurements, bridging the gap between atmospheric and ecosystem monitoring networks. The ICOS Cities (PAUL) project aims to monitor CO 2 emissions in urban areas, where concentrated emissions make them key targets for climate change mitigation. This study explores the synergy between ICOS atmospheric and ecosystem networks by utilizing slow-response analysers (∼ 3 s) on tall atmospheric towers for ecosystem studies using the eddy covariance method. A standard setup with an ultrasonic anemometer and an infrared (IR) fast-response CO 2 analyser was installed and compared with measurements from an existing cavity ringdown spectroscopy (CRDS) analyser measuring CO 2 , CO, and CH 4 . Deployed on the 100 m Saclay tower near Paris, covering a 43.9 km 2 80 % footprint with heavy traffic roads, a nearby heating plant, and a forest, the setup addressed technical challenges and height-induced complexities. Corrections for flux attenuation by high-frequency losses were limited to < 20 % on average for all stabilities and around 11 % for unstable conditions. Elevated mean fluxes for CO 2 (10 µmol m -2 s -1 ) and CH 4 (200 µmol m -2 s -1 ) were observed from the heating plant wind direction during December and January. Conversely, the forest direction exhibited the strongest sink among all wind directions, with -4 µmol m -2 s -1 during July and August. Storage and vertical advection were estimated using the routine three-level profile measurements done in ICOS atmospheric towers.

Storage term was of the same magnitude as turbulent flux, increasing at night and de-stocking during the first half of the day. Vertical advection averaged zero on a monthly basis. These results demonstrate the feasibility and versatility of utilizing atmospheric towers for urban emission monitoring, offering valuable insights for emission monitoring strategies worldwide.

Fichier principal
Vignette du fichier
amt-17-6625-2024.pdf (4.26 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-04803967 , version 1 (26-11-2024)

Licence

Identifiants

Citer

Pedro Henrique Herig Coimbra, Benjamin Loubet, Olivier Laurent, Laura Bignotti, Mathis Lozano, et al.. Eddy covariance with slow-response greenhouse gas analysers on tall towers: bridging atmospheric and ecosystem greenhouse gas networks. Atmospheric Measurement Techniques, 2024, 17 (2), pp.6625 - 6645. ⟨10.5194/amt-17-6625-2024⟩. ⟨hal-04803967⟩
0 Consultations
0 Téléchargements

Altmetric

Partager

More