Article Dans Une Revue Fusion Engineering and Design Année : 2001

Design criteria for Tore Supra high heat flux components

Résumé

The need of high heat flux components (HHFCs) is significant in the fusion community. Such elements are required for divertor or limiter applications. The optimisation between performance and safety involved a large investment on design criteria. Based on the actual Tore Supra (TS) feedback and the recent work for Composant Interne Et Limiteur (CIEL) project with the newly developed component for Toroidal Pump Limiter (TPL), a review of the major thermal and mechanical design criteria is detailed in this paper.

Fichier principal
Vignette du fichier
Article FED-2001 --- Design criteria for Tore Supra HHF components.pdf (205.56 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Licence

Dates et versions

hal-04620008 , version 1 (02-10-2024)

Licence

Identifiants

Citer

Marc Missirlian, J Schlosser, M Lipa, R Mitteau, Ph Chappuis, et al.. Design criteria for Tore Supra high heat flux components. Fusion Engineering and Design, 2001, 56-57, pp.457-463. ⟨10.1016/S0920-3796(01)00327-1⟩. ⟨hal-04620008⟩