Marker‐based C‐arm self‐calibration with unknown calibration pattern - Archive ouverte HAL
Article Dans Une Revue Medical Physics Année : 2024

Marker‐based C‐arm self‐calibration with unknown calibration pattern

Résumé

Abstract Background Accurate tomographic reconstructions require the knowledge of the actual acquisition geometry. Many mobile C‐arm CT scanners have poorly reproducible acquisition geometries and thus need acquisition‐specific calibration procedures. Most of geometric self‐calibration methods based on projection data either need prior information or are limited to the estimation of a low number of geometric calibration parameters. Other self‐calibration methods generally use a calibration pattern with known geometry and are hardly implementable in practice for clinical applications. Purpose We present a three‐step marker based self‐calibration method which does not require the prior knowledge of the calibration pattern and thus enables the use of calibration patterns with arbitrary markers positions. Methods The first step of the method aims at detecting the set of markers of the calibration pattern in each projection of the CT scan and is performed using the YOLO (You Only Look Once) Convolutional Neural Network. The projected marker trajectories are then estimated by a sequential projection‐wise marker association scheme based on the Linear Assignment Problem which uses Kalman filters to predict the markers 2D positions in the projections. The acquisition geometry is finally estimated from the marker trajectories using the Bundle‐adjustment algorithm. Results The calibration method has been tested on realistic simulated images of the ICRP (International Commission on Radiological Protection) phantom, using calibration patterns with 10 and 20 markers. The backprojection error was used to evaluate the self‐calibration method and exhibited sub‐millimeter errors. Real images of two human knees with 10 and 30 markers calibration patterns were then used to perform a qualitative evaluation of the method, which showed a remarkable artifacts reduction and bone structures visibility improvement. Conclusions The proposed calibration method gave promising results that pave the way to patient‐specific geometric self‐calibrations in clinics.

Mots clés

Fichier non déposé

Dates et versions

hal-04614868 , version 1 (17-06-2024)

Identifiants

Citer

Odran Pivot, Sandrine Voros, Christine Chappard, Guillaume Bernard, Yannick Grondin, et al.. Marker‐based C‐arm self‐calibration with unknown calibration pattern. Medical Physics, 2024, 51 (6), pp.4056-4068. ⟨10.1002/mp.17098⟩. ⟨hal-04614868⟩
464 Consultations
0 Téléchargements

Altmetric

Partager

More