Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

Samuel Dorey
  • Fonction : Auteur
  • PersonId : 1086384
Yelin Ni
Donghui Li
  • Fonction : Auteur
  • PersonId : 1355185
Mark K Murphy
  • Fonction : Auteur
  • PersonId : 1355186
Leonard S Fifield

Résumé

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/ EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV-Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV-Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.
Fichier principal
Vignette du fichier
rad phys chem.pdf (4.74 Mo) Télécharger le fichier
Origine Publication financée par une institution
Licence

Dates et versions

hal-04470509 , version 1 (21-02-2024)

Licence

Identifiants

Citer

Blanche Krieguer, Sylvain R A Marque, Samuel Dorey, Fabien Girard, Yelin Ni, et al.. Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data. Radiation Physics and Chemistry, 2024, 218, ⟨10.1016/j.radphyschem.2024.111607⟩. ⟨hal-04470509⟩
108 Consultations
72 Téléchargements

Altmetric

Partager

More