RESPIRATION-RELATED VARIATIONS IN CENTRAL VENOUS PRESSURE AS PREDICTORS OF FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING PATIENTS - Archive ouverte HAL
Article Dans Une Revue Shock Année : 2023

RESPIRATION-RELATED VARIATIONS IN CENTRAL VENOUS PRESSURE AS PREDICTORS OF FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING PATIENTS

Claire Bourel
  • Fonction : Auteur
Arthur Durand
  • Fonction : Auteur
Benoit ter Schiphorst
  • Fonction : Auteur
Claire Martin
  • Fonction : Auteur
Thierry Onimus
  • Fonction : Auteur
Michael Howsam
Raphael Favory
  • Fonction : Auteur
Sebastien Preau

Résumé

ABSTRACT Objective : The hemodynamic parameters used to accurately predict fluid responsiveness (FR) in spontaneously breathing patients (SB) require specific material and expertise. Measurements of the central venous pressure (CVP) are relatively simple and, importantly, are feasible in many critically ill patients. We analyzed the accuracy of respiration-related variations in CVP (vCVP) to predict FR in SB patients and examined the optimization of its measurement using a standardized, deep inspiratory maneuver. Patients and Methods : We performed a monocentric, prospective, diagnostic evaluation. Spontaneously breathing patients in intensive care units with a central venous catheter were prospectively included. The vCVP was measured while the patient was spontaneously breathing, both with (vCVP-st) and without (vCVP-ns) a standardized inspiratory maneuver, and calculated as: Minimum inspiratory v-wave peak pressure − Maximum expiratory v-wave peak pressure. A passive leg raising-induced increase in the left ventricular outflow tract velocity-time integral ≥10% defined FR. Results : Among 63 patients, 38 (60.3%) presented FR. The vCVP-ns was not significantly different between responders and nonresponders (−4.9 mm Hg [−7.5 to −3.1] vs. −4.1 mm Hg [−5.4 to 2.8], respectively; P = 0.15). The vCVP-st was lower in responders than nonresponders (−9.7 mm Hg [−13.9 to −6.2] vs. −3.6 mm Hg [−10.6 to −1.6], respectively; P = 0.004). A vCVP-st < −4.7 mm Hg predicted FR with 89.5% sensitivity, a specificity of 56.0%, and an area under the receiver operating characteristic curve of 0.72 (95% CI, 0.58 to 0.86) ( P = 0.004). Conclusion : When a central venous catheter is present, elevated values for vCVP-st may be useful to identify spontaneously breathing patients unresponsive to volume expansion. Nevertheless, the necessity of performing a standardized, deep-inspiration maneuver may limit its clinical application.
Fichier non déposé

Dates et versions

hal-04399144 , version 1 (17-01-2024)

Identifiants

Citer

Claire Bourel, Arthur Durand, Benoit ter Schiphorst, Claire Martin, Thierry Onimus, et al.. RESPIRATION-RELATED VARIATIONS IN CENTRAL VENOUS PRESSURE AS PREDICTORS OF FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING PATIENTS. Shock, 2023, 60 (2), pp.190-198. ⟨10.1097/SHK.0000000000002164⟩. ⟨hal-04399144⟩
24 Consultations
0 Téléchargements

Altmetric

Partager

More