Impact of solvent on ammonia detection performance of polyaniline-based sensors - Archive ouverte HAL
Conference Papers Year : 2023

Impact of solvent on ammonia detection performance of polyaniline-based sensors

Abstract

Ammonia constitutes a polluting gas in the atmosphere. Chemiresistive sensors based on the polyaniline (PAni) can be used to monitor it. In this technology, the doped PAni is dispersed in a solvent like m-cresol, n-methyl-2-pyrrolidone or dichloroacetic acid, as reported in the literature. However, these solvents cause environmental and toxicity issues. This study aims to identify a safer solvent for PAni formulation displaying efficient gas sensing performances. Several alternative organic solvents were selected and tested in the formulation of PAni doped with camphorsulfonic acid. PAni-films morphology was characterized using SEM. Sensing performances of those materials formulated with various solvents have been evaluated at different ammonia concentrations. The role of the active layer morphology on the sensing performance has been specially discussed.
No file

Dates and versions

hal-04249270 , version 1 (19-10-2023)

Identifiers

  • HAL Id : hal-04249270 , version 1

Cite

Sabine Vassaux, Nathalie Redon, Edilene Assunção da Silva, Caroline Duc. Impact of solvent on ammonia detection performance of polyaniline-based sensors. 9th International Conference on Sensors Engineering and Electronics Instrumentation Advances (SEIA), Sep 2023, Funchal (Madeira Island), Portugal. ⟨hal-04249270⟩