Templates of expected measurement uncertainties for average prompt and total fission neutron multiplicities
Résumé
In this paper, we provide templates of measurement uncertainty sources expected to appear for average prompt-and total-fission neutron multiplicities, $\bar{v}_p$ and $\bar{v}_t$ , for the following measurement types: Absolute manganese-bath experiments for $\bar{v}_t$ , absolute and ratio liquid-scintillator measurements for $\bar{v}_p$. These templates also suggest a typical range of these uncertainties and their correlations based on a survey of available experimental data, associated literature, and feedback from experimentalists. In addition, information needed to faithfully include the associated experimental data into the nuclear-data evaluation process are provided.
Fichier principal
Templates_of_Expected_Measurement_Uncertainties_for_Average_Prompt_and_Total_Fission_Neutron_Multiplicities.pdf (790.56 Ko)
Télécharger le fichier
Origine | Fichiers produits par l'(les) auteur(s) |
---|