Effectiveness of staff radiation protection devices for interventional cardiology procedures

Résumé

To evaluate the effectiveness of currently available radioprotective (RP) devices in reducing the dose to interventional cardiology staff, especially to the eye lens and brain. Methods: The performances of five RP devices (masks, caps, patient drapes, staff lead and lead-free aprons and Zero-Gravity (ZG) suspended radiation protection system) were assessed by means of Monte Carlo (MC) simu lations. A geometry representative of an interventional cardiology setup was modelled and several configura tions, including beam projections and staff distance from the source, were investigated. In addition, measurements on phantoms were performed for masks and drapes. Results: An average dose reduction of 65% and 25% to the eyes and the brain respectively was obtained for the masks by MC simulations but a strong influence of the design was observed. The cap effectiveness for the brain ranges on average between 13% and 37%. Nevertheless, it was shown that only some upper parts of the brain were protected. There was no significant difference between the effectiveness of lead and lead-free aprons. Of all the devices, the ZG system offered the highest protection to the brain and eye lens and a protection level comparable to the apron for the organs normally covered. Conclusion: All investigated devices showed potential for dose reduction to specific organs. However, for masks, caps and drapes, it strongly depends on the design, exposure conditions and staff position. Therefore, for a clinical use, it is recommended to evaluate their effectiveness in the planned conditions of use.
Fichier principal
Vignette du fichier
3_Huetetal_2023.PDF (10.4 Mo) Télécharger le fichier
Origine : Publication financée par une institution
Licence : CC BY NC ND - Paternité - Pas d'utilisation commerciale - Pas de modification

Dates et versions

hal-04163548 , version 1 (17-07-2023)

Licence

Paternité - Pas d'utilisation commerciale - Pas de modification

Identifiants

Citer

Christelle Huet, Jérémie Dabin, Joanna Domienik-Andrzejewska, Alexandre Hebre, Edilaine Honorio da Silva, et al.. Effectiveness of staff radiation protection devices for interventional cardiology procedures. Physica Medica, 2023, 107, pp.102543. ⟨10.1016/j.ejmp.2023.102543⟩. ⟨hal-04163548⟩

Collections

IRSN PSESANTE SDOS
16 Consultations
13 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More