Between-sessions test-retest reliability of prefrontal cortical activity during usual walking in patients with Parkinson’s Disease: A fNIRS study

Résumé

Background: Examining between-sessions test-retest reliability of functional near-infrared spectroscopy (fNIRS) data is crucial to better interpret rehabilitation-related changes in the hemodynamic response. Research question: This study investigated test-retest reliability of prefrontal activity during usual walking in 14 patients with Parkinson's Disease with a fixed retest intervals of five weeks. Methods: Fourteen patients performed usual walking in two sessions (T0 and T1). Relative changes in cortical activity (oxy and deoxyhemoglobin: ΔHbO 2 and ΔHbR, respectively) in the dorsolateral prefrontal cortex (DLPFC) using fNIRS system and gait performance were measured. Test-retest reliability of mean ΔHbO 2 for the total DLPFC and for each hemisphere were measured using paired t-test, intraclass correlation coefficient (ICC), and Bland-Altman plots with 95% agreement. Pearson correlations between cortical activity and gait performance were also performed. Results: Moderate reliability was found for ΔHbO 2 in the total DLPFC (mean difference of ΔHbO 2 between T1 and T0 = − 0.005 µmol, p = 0.93; ICC average = 0.72). However, test-retest reliability of ΔHbO 2 was poorer when considering each hemisphere. Significance: Findings suggest that fNIRS may be used as a reliable tool for rehabilitation studies in patients with PD. Test-retest reliability of fNIRS data between 2 sessions during walking tasks should be interpreted respectively of gait performance.
Fichier principal
Vignette du fichier
Ranchet et al., 2023, PREPRINT VERSION.pdf (430.92 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04157290 , version 1 (09-01-2024)

Identifiants

Citer

M Ranchet, I Hoang, R Derollepot, L Paire-Ficout. Between-sessions test-retest reliability of prefrontal cortical activity during usual walking in patients with Parkinson’s Disease: A fNIRS study. Gait & Posture, 2023, 103, pp.99 - 105. ⟨10.1016/j.gaitpost.2023.05.003⟩. ⟨hal-04157290⟩
9 Consultations
9 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More