Article Dans Une Revue Materials and structures Année : 2023

RILEM TC 266-MRP - Round-Robin Rheological Tests on High Performance Mortar and Concrete with Adapted Rheology: Evaluating Structural Build-up at Rest of Mortar and Concrete

Sofiane Amziane
Kamal Khayat
  • Fonction : Auteur
Mohammed Sonebi
  • Fonction : Auteur
Arnaud Perrot

Résumé

Abstract This paper presents the results of a round-robin testing program undertaken by RILEM TC-266 - Measuring Rheological Properties of Cement-Based Materials in May 2018 at the Université d’Artois in Bethune France. Five types of rheometers were compared, they consisted of four ICAR rheometers, Viskomat XL rheometer, eBT-V rheometer, Sliding Pipe Rheometer (SLIPER), RheoCAD rheometer, and 4SCC rheometer, as well as the plate test. This paper discusses the results of the evolution of the static yield stress at rest of three mortar and five concrete mixtures that were determined using two ICAR rheometers, Viscomat XL and eBT-V rheometers, and the plate test. For the measurements carried out with rheometers, three different structural build-up indices (i.e., structural build-up rate, critical time, and coupled effects of initial static yield stress and rate of structural build-up) were determined. The indices were established using two static yield stress values measured after 10 and 40 minutes of rest as well as three static yield stress values that combine the two static yield stress measurements and the initial dynamic yield stresses obtained from the flow curves. The paper discusses the test results and highlights inaccuracies that could be encountered in determining the static yield stress. Test results indicate that the ICAR rheometers and the selected thixotropic indices can provide similar results, and that the spread of results obtained from different rheometers can be considerably reduced when using three yield stress values to calculate the rate of the static yield stress at rest. In order to enhance the accuracy of measurements, it is recommended to increase the number of measurements of the yield stress to at least three points over one hour after mixing to determine more accurately the various thixotropy indices.
Fichier non déposé

Dates et versions

hal-04153798 , version 1 (06-07-2023)

Identifiants

Citer

Sofiane Amziane, Kamal Khayat, Mohammed Sonebi, Arnaud Perrot. RILEM TC 266-MRP - Round-Robin Rheological Tests on High Performance Mortar and Concrete with Adapted Rheology: Evaluating Structural Build-up at Rest of Mortar and Concrete. Materials and structures, inPress, ⟨10.21203/rs.3.rs-2828827/v1⟩. ⟨hal-04153798⟩
5 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More