Evaluation of maximum non-metallic inclusion sizes in steel by statistics of extreme values method based on Micro-CT imaging - Archive ouverte HAL
Article Dans Une Revue Metallurgical Research & Technology Année : 2022

Evaluation of maximum non-metallic inclusion sizes in steel by statistics of extreme values method based on Micro-CT imaging

Linan Tian
  • Fonction : Auteur
Long Liu
  • Fonction : Auteur
Bo Ma
  • Fonction : Auteur
Ning Ding
  • Fonction : Auteur
Weimin Guo
  • Fonction : Auteur
Na Xu
  • Fonction : Auteur
Huixia Xu
  • Fonction : Auteur
Ming Zhang
  • Fonction : Auteur

Résumé

Non-metallic inclusions have become a matter of concern for several properties of steel. The effective evaluation of inclusions in steel would provide critical information to evaluate the steel quality. In this study, an evaluation method based on X-ray Micro-Computed Tomography (Micro-CT) experiments was proposed. First, Micro-CT experiments were carried out to characterize the inclusions. Then, the characterizations of the inclusions were collected based on the 2D slices and their 3D features. The extreme values were evaluated by statistics of extreme values method with these data. The evaluation results were compared with those obtained by international standard ASTM E2283-08. The results demonstrated that the evaluation method based on inclusion sizes collected from 3D inclusion information provided a stable result. It means that the extreme value evaluation method with the 3D data based on Micro-CT was an effective method.

Dates et versions

hal-04128371 , version 1 (14-06-2023)

Identifiants

Citer

Linan Tian, Long Liu, Bo Ma, Fahmi Zaïri, Ning Ding, et al.. Evaluation of maximum non-metallic inclusion sizes in steel by statistics of extreme values method based on Micro-CT imaging. Metallurgical Research & Technology, 2022, 119 (2), pp.202. ⟨10.1051/metal/2022016⟩. ⟨hal-04128371⟩