Electrophoretic displays for IR emissivity modulation and temperature control
Résumé
The first electrophoretic display capable of IR dynamic modulation for temperature control was fabricated and evaluated. The apparent temperature observed with IR cameras was modulated by 4 °C in LWIR and by 10 °C in MWIR.