Assessing rheometry for measuring the viscosity-average degree of polymerisation of cellulose in paper degradation studies - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Heritage Science Année : 2023

Assessing rheometry for measuring the viscosity-average degree of polymerisation of cellulose in paper degradation studies

Résumé

Abstract In paper degradation studies, the viscosity-average degree of polymerisation (DP v ) is often used as a key indicator of the extent of degradation of cellulosic paper. DP v can be deduced from the viscosity of dilute paper solutions, as typically measured through glass capillary viscometry. The current study proposes an efficient, alternative method to evaluate DP v of cellulosic paper, which is based on rotational rheometry. The proposed methodology relies on the application of a shear flow in a thin film of cellulose solution to measure its dynamic viscosity, from which DP v can be subsequently derived in a straightforward fashion. Rheometry allows to measure the viscosity for a range of shear rates, which results in multiple DP v evaluations per sample, and thus in statistically representative data from an individual test. Further, rheometry typically requires considerably less paper mass per test than glass capillary viscometry, which makes the method attractive for paper degradation studies with limited sample availability. Also, rheometry measurements are less work-intensive than glass capillary viscometry measurements. The rheometry method has been applied to 4 hygrothermally aged cellulose paper samples and the unaged counterpart. The measurement results regarding the age-dependency of DP v and the number of cellulose chain scissions are compared to those obtained by glass capillary viscometry, showing a very good agreement. At a longer ageing time, both experimental methods reveal a non-linear decrease in time of DP v , and a non-linear increase in time of the number of cellulose chain scissions, which indicate that the cellulose ageing process is realistically captured. The agreement in measurement results further demonstrates that rheometry is an easy-to-use, accurate and efficient alternative for DP v measurements by glass capillary viscometry.
Fichier principal
Vignette du fichier
Maraghechi_rheom visc cell_HeritSci23.pdf (1.2 Mo) Télécharger le fichier
Origine : Publication financée par une institution

Dates et versions

hal-03960500 , version 1 (27-01-2023)

Identifiants

Citer

Siavash Maraghechi, Anne-Laurence Dupont, Ruth Cardinaels, Sabrina Paris-Lacombe, Johan P M Hoefnagels, et al.. Assessing rheometry for measuring the viscosity-average degree of polymerisation of cellulose in paper degradation studies. Heritage Science, 2023, 11 (1), pp.15. ⟨10.1186/s40494-022-00855-7⟩. ⟨hal-03960500⟩

Collections

MNHN CNRS
90 Consultations
21 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More