Field Emission Studies During ESS Cryomodule Tests at CEA Saclay
Résumé
For the development of efficient superconducting cavi-ties, field emission is an important parasitic phenomena to monitor. A diagnostic system composed of Geiger-Mueller (G-M) probes, NaI(Tl) scintillators are placed in the cryomodule test stand. Collected data is analysed and confronted to particle tracking simulation and electro magnetic shower code. With such systematic analysis we aim to identify the most probable field emission location and hence help to improve clean procedures during as-sembly and operation.