Ionic transport properties in solid polymer electrolytes: in-plane versus through-plane
Résumé
➢ In PEO and PS-PEO, anisotropy mainly due to the variation of D+ and impact of transference number t+
➢ The anisotropy experimentally measured may due to chain morphology along Ʇ and //
➢ In Ʇ for single-ion conductors, the passivation layers play a main role in the t+ determination