Digital Volume Correlation for Large Deformations of Soft Tissues: Pipeline and Proof of Concept for the application to Breast ex vivo Deformations
Résumé
Being able to reposition tumors from prone imaging to supine surgery stances is key for bypassing current invasive marking used for conservative breast surgery. This study aims to demonstrate the feasibility of using Digital Volume Correlation (DVC) to measure the deformation of a female quarter thorax between two different body positioning when subjected to gravity. A segmented multipart mesh (bones, cartilage and tissue) was constructed and a three-step FE-based DVC procedure with heterogeneous elastic regularization was implemented. With the proposed framework, the large displacement field of a mixed hard/soft breast sample was recovered with low registration residuals and low error between the measured and the manually determined deformations of inter-phase interfaces. The present study showed the capacity of FE-based DVC to faithfully capture large deformations of hard/soft tissues.