3D Transcranial Ultrasound Localization Microscopy in the Rat Brain With a Multiplexed Matrix Probe - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE Transactions on Biomedical Engineering Année : 2022

3D Transcranial Ultrasound Localization Microscopy in the Rat Brain With a Multiplexed Matrix Probe

Résumé

Objective: Ultrasound Localization Microscopy (ULM) provides images of the microcirculation in-depth in living tissue. However, its implementation in two-dimension is limited by the elevation projection and tedious plane-by-plane acquisition. Volumetric ULM alleviates these issues and can map the vasculature of entire organs in one acquisition with isotropic resolution. However, its optimal implementation requires many independent acquisition channels, leading to complex custom hardware. Methods: In this article, we implemented volumetric ultrasound imaging with a multiplexed 32 × 32 probe driven by a single commercial ultrasound scanner. We propose and compare three different sub-aperture multiplexing combinations for localization microscopy in silico and in vitro with a flow of microbubbles in a canal. Finally, we evaluate the approach for micro-angiography of the rat brain. The “light” combination allows a higher maximal volume rate than the “full” combination while maintaining the field of view and resolution. Results: In the rat brain, 100,000 volumes were acquired within 7 min with a dedicated ultrasound sequence and revealed vessels down to 31 μm in diameter with flows from 4.3 mm/s to 28.4 mm/s. Conclusion: This work demonstrates the ability to perform a complete angiography with unprecedented resolution in the living rat's brain with a simple and light setup through the intact skull. Significance: We foresee that it might contribute to democratize 3D ULM for both preclinical and clinical studies.
Fichier principal
Vignette du fichier
Chavignon_3DtULM_2022.pdf (6.14 Mo) Télécharger le fichier
Supplementary_video_1.mp4 (9.51 Mo) Télécharger le fichier
Supplementary_video_2.mp4 (10.8 Mo) Télécharger le fichier
Supplementary_video_3.mp4 (10.11 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Format : Vidéo
Commentaire : ULM of a rat brain with an intact skull. 3D rendering of the microvascular with Amira (ThermoFisher).
Format : Vidéo
Commentaire : ULM of a rat brain with an intact skull. 500 µm coronal slices of the hemodynamic volume up to 30 mm/s. Flows are encoded yellow to red (positive) for upward flows, and green to blue (negative) for downward flows.
Format : Vidéo
Commentaire : ULM of a rat brain with an intact skull. 3D rendering with alpha composition of in vivo ULM compared to ex vivo micro-CT.

Dates et versions

hal-03719050 , version 1 (10-07-2022)

Identifiants

Citer

Arthur Chavignon, Baptiste Heiles, Vincent Hingot, Cyrille Orset, Denis Vivien, et al.. 3D Transcranial Ultrasound Localization Microscopy in the Rat Brain With a Multiplexed Matrix Probe. IEEE Transactions on Biomedical Engineering, 2022, 69 (7), pp.2132-2142. ⟨10.1109/TBME.2021.3137265⟩. ⟨hal-03719050⟩
70 Consultations
100 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More