Multiple-Cell Microfluidic Dielectric Resonator for Liquid Sensing Applications - Archive ouverte HAL
Article Dans Une Revue IEEE Sensors Journal Année : 2021

Multiple-Cell Microfluidic Dielectric Resonator for Liquid Sensing Applications

Résumé

This paper presents a high-sensitive planar microwave sensor based on the metamaterial technology, integrated with a microfluidic channel to be used for liquid sensing in a variety of biomedical applications. The sensor design comprises three cells of circular complementary split ring resonators (CSRRs) engraved on the ground plane of a dielectric substrate in a cascaded configuration. The sensing cells are excited with a time-varying electric field coupled from a planar microstrip-line (MTL) etched on the bottom side of the substrate. The proposed design of multiple coupled resonators would enhance the electric field intensity over a larger sensing region through the inter-resonator coupling, thus improving the overall sensitivity for detecting liquid samples of high permittivity and dielectric losses. The sensor exhibits a reject (band stop) filter behaviour with multiple resonances in the centimeter-wave band 1 - 6 GHz when loaded symmetrically with liquid samples. The sensor is fabricated on an FR4 dielectric substrate with a biocompatible microfluidic channel aligned appropriately over the sensing area to enable consistent and intact sensing of the liquid samples. The CSSR-sensor is numerically modeled and compared in performance to the single-cell CSRR for detecting small variations in the dielectric properties. The sensitivity, reliability, and repeatability of the proposed sensor are practically demonstrated by the in-lab measurements for different liquid samples using a Vector Network Analyzer (VNA) setup where distinctive resonant features (amplitude and frequency) are extracted from multiple resonance modes in the reflection and transmission responses. A high sensitivity is also demonstrated for monitoring glucose level variations in synthetic blood samples of concentrations (70 - 150 mg/dL) which are clinically-relevant to diabetes conditions. Beside its impressive capability in detecting small dielectric variations, the developed sensor features other f...
Fichier non déposé

Dates et versions

hal-03597238 , version 1 (04-03-2022)

Identifiants

Citer

Ala Eldin Omer, George Shaker, Safieddin Safavi-Naeini, Kieu Ngo, Raed M Shubair, et al.. Multiple-Cell Microfluidic Dielectric Resonator for Liquid Sensing Applications. IEEE Sensors Journal, 2021, 21 (5), pp.6094-6104. ⟨10.1109/JSEN.2020.3041700⟩. ⟨hal-03597238⟩
66 Consultations
0 Téléchargements

Altmetric

Partager

More