Comparison of local electrochemical impedance measurements derived frombi-electrode and microcapillary techniques - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Electrochimica Acta Année : 2009

Comparison of local electrochemical impedance measurements derived frombi-electrode and microcapillary techniques

Résumé

In the present paper, local electrochemical impedance spectrawere obtained on a 316L stainless steel from two configurations: a dual microelectrode (bi-electrode) and microcapillaries. With the bi-electrode, the local impedance measurements were made from the ratio of the applied voltage to the local current density calculated from the application of the ohm’s law. With the use of microelectrochemical cells, the specimen surface area in contact with the electrolyte is limited by the use of glass microcapillaries and the local impedance was defined fromthe ratio of the local potential to the local current restricted to the analysed surface area. Differences and similarities observed in local impedance spectra obtained with the two configurations were described
Fichier principal
Vignette du fichier
Jorcin_3819.pdf (299.11 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03566004 , version 1 (11-02-2022)

Identifiants

Citer

Jean-Baptiste Jorcin, Halina Krawiec, Nadine Pébère, Vincent Vignal. Comparison of local electrochemical impedance measurements derived frombi-electrode and microcapillary techniques. Electrochimica Acta, 2009, 54 (24), pp.5775 -5781. ⟨10.1016/j.electacta.2009.05.029⟩. ⟨hal-03566004⟩
10 Consultations
32 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More