Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Clinical Gastroenterology and Hepatology Année : 2020

Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease

Résumé

Background & aims: Inter-platform variation in liver stiffness evaluation (LSE) could hinder dissemination and clinical implementation of new ultrasound methods. We aimed to determine whether measurements of liver stiffness by bi-dimensional shear wave elastography (2D-SWE) with a Supersonic Imagine apparatus are comparable to those made by vibration-controlled transient elastography (VCTE).Methods: We collected data from 1219 consecutive patients with chronic liver disease who underwent LSE by VCTE and 2D-SWE (performed by blinded operators), on the same day, at a single center in France from September 2011 through June 2019. We assessed the ability of liver stiffness value distributions and 2D-SWE performances to identify patients with compensated advanced chronic liver disease (cACLD) according to the Baveno VI criteria, based on VCTE cut-off values.Results: VCTE and 2D-SWE values correlated (Pearson's correlation coefficient, 0.882; P < .0001; Lin concordance coefficient, 0.846; P < .0001). The median stiffness values were 6.7 kPa with VCTE (interquartile range, 4.8-11.6 kPa) and 7.1 kPa with 2D-SWE (interquartile range, 5.4-11.1 kPa) (P = .736). 2D-SWE values were slightly higher in the low percentiles and lower in the high percentiles; the best match with VCTE values were at approximately 7-9 kPa. The area under the curve of 2D-SWE for identifying of VCTE values below 10 was 0.964 (95% CI, 0.952-0.976) and for VCTE values above 15 kPa was 0.976 (95% CI, 0.963-0.988), with Youden index-associated cut-off values of 9.5 and 13kPa and best accuracy cut-off values of 10 kPa and 14 kPa, respectively. A 2D-SWE cut-off value of 10 kPa detected VCTE values below 10k Pa with 92% sensitivity, 87% specificity, and 91% accuracy.Conclusions: Measurement of liver stiffness by VCTE or 2D-SWE produces comparable results. 2D-SWE accurately identifies patients with cACLD according to the Baveno VI criteria based on VCTE cut-off values. A 10 kPa 2D-SWE cut-off value can be used to rule out cACLD.
Fichier principal
Vignette du fichier
S1542356520305310.pdf (1.51 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-03492708 , version 1 (21-11-2022)

Licence

Paternité - Pas d'utilisation commerciale

Identifiants

Citer

Christophe Cassinotto, Bruno Lapuyade, Boris Guiu, Hortense Marraud Des Grottes, Lauranne Piron, et al.. Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease. Clinical Gastroenterology and Hepatology, 2020, 18, pp.2971 - 2979.e3. ⟨10.1016/j.cgh.2020.04.034⟩. ⟨hal-03492708⟩
1058 Consultations
23 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More