Validity, reliability, and responsiveness of daily monitoring visual analog scales in MASK-air®

Bernardo Sousa-Pinto
Patrik E. Eklund
  • Fonction : Auteur
Oliver Pfaar
Ludger Klimek
Thorsten Zuberbier
  • Fonction : Auteur
Wienczyslawa Czarlewski
Carsten Bindslev-Jensen
Anna Bedbrook
Sinthia Bosnic-Anticevich
  • Fonction : Auteur
Luisa Brussino
Victoria Cardona
Álvaro Augusto Cruz
  • Fonction : Auteur
Govert de Vries
  • Fonction : Auteur
Wytske Johanna Fokkens
  • Fonction : Auteur
José Miguel Fuentes-Pérez
  • Fonction : Auteur
Bilun Gemicioğlu
Tari M.K. Haahtela
  • Fonction : Auteur
J. C. Ivancevich
Inger Kull
  • Fonction : Auteur
P. Kuna
Violeta Kvedariene
  • Fonction : Auteur
Désirée E.S. Larenas Linnemann
Daniel Laune
  • Fonction : Auteur
Michaël P. Makris
  • Fonction : Auteur
Erik Melén
  • Fonction : Auteur
Mário A. Morais-Almeida
  • Fonction : Auteur
Ralph Mösges
Joaquim Mullol
Robyn E. O'Hehir
N. G. Papadopoulos
Ana Margarida Pereira
Emmanuel P. Prokopakis
  • Fonction : Auteur
Fotis Psarros
  • Fonction : Auteur
Frederico Regateiro
Sietze Reitsma
  • Fonction : Auteur
Bolesław Samolinski
  • Fonction : Auteur
Nicola Scichilone
Jane da Silva
  • Fonction : Auteur
Cristiana Stellato
A. Todo-Bom
Peter Valentin Tomazic
Sanna Toppila Salmi
  • Fonction : Auteur
Antonio Luís Valero
  • Fonction : Auteur
Arūnas Valiulis
  • Fonction : Auteur
Erkka Juhani Valovirta
  • Fonction : Auteur
Michiel van Eerd
  • Fonction : Auteur
M. T. Ventura
Arzu Yorgancioglu
X. Basagaña
Josep Maria Antó
  • Fonction : Auteur
João Almeida Fonseca

Résumé

Background: MASK-air® is an app that supports allergic rhinitis patients in disease control. Users register daily allergy symptoms and their impact on activities using visual analog scales (VASs). We aimed to assess the concurrent validity, reliability, and responsiveness of these daily VASs. Methods: Daily monitoring VAS data were assessed in MASK-air® users with allergic rhinitis. Concurrent validity was assessed by correlating daily VAS values with those of the EuroQol-5 Dimensions (EQ-5D) VAS, the Control of Allergic Rhinitis and Asthma Test (CARAT) score, and the Work Productivity and Activity Impairment Allergic Specific (WPAI-AS) Questionnaire (work and activity impairment scores). Intra-rater reliability was assessed in users providing multiple daily VASs within the same day. Test–retest reliability was tested in clinically stable users, as defined by the EQ-5D VAS, CARAT, or “VAS Work” (i.e., VAS assessing the impact of allergy on work). Responsiveness was determined in users with two consecutive measurements of EQ-5D-VAS or “VAS Work” indicating clinical change. Results: A total of 17,780 MASK-air® users, with 317,176 VAS days, were assessed. Concurrent validity was moderate–high (Spearman correlation coefficient range: 0.437–0.716). Intra-rater reliability intraclass correlation coefficients (ICCs) ranged between 0.870 (VAS assessing global allergy symptoms) and 0.937 (VAS assessing allergy symptoms on sleep). Test–retest reliability ICCs ranged between 0.604 and 0.878—“VAS Work” and “VAS asthma” presented the highest ICCs. Moderate/large responsiveness effect sizes were observed—the sleep VAS was associated with lower responsiveness, while the global allergy symptoms VAS demonstrated higher responsiveness. Conclusion: In MASK-air®, daily monitoring VASs have high intra-rater reliability and moderate–high validity, reliability, and responsiveness, pointing to a reliable measure of symptom loads.

Domaines

Allergologie
Fichier principal
Vignette du fichier
CLT2-11-e12062.pdf (541.14 Ko) Télécharger le fichier
Origine Publication financée par une institution

Dates et versions

hal-03401816 , version 1 (30-05-2022)

Licence

Identifiants

Citer

Bernardo Sousa-Pinto, Patrik E. Eklund, Oliver Pfaar, Ludger Klimek, Thorsten Zuberbier, et al.. Validity, reliability, and responsiveness of daily monitoring visual analog scales in MASK-air®. Clinical and Translational Allergy, 2021, 11 (7), ⟨10.1002/clt2.12062⟩. ⟨hal-03401816⟩
24 Consultations
42 Téléchargements

Altmetric

Partager

More