One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients - Archive ouverte HAL
Article Dans Une Revue The Clinical Respiratory Journal Année : 2018

One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients

Gregory Reychler
  • Fonction : Auteur
Eliott Boucard
  • Fonction : Auteur
Loïc Peran
  • Fonction : Auteur
Romain Pichon
  • Fonction : Auteur
Catherine Le Ber-Moy
  • Fonction : Auteur
Hakima Ouksel
  • Fonction : Auteur
Giuseppe Liistro
  • Fonction : Auteur
Marc Beaumont

Résumé

Introduction: Chronic obstructive pulmonary disease (COPD) is frequently associated with a reduced functional exercise performance. Even if this parameter is routinely evaluated using 6-minute walking test (6MWT), new field tests are regularly investigated as alternative tests. The aim of this study was to compare functional exercise performance evaluation by sit-to-stand test (STST) and 6MWT and to evaluate reliability and repeatability of the STST in COPD patients. Method: Forty-two COPD patients performed randomly two tests: 6MWT and STST. Each test was repeated two times. Distance (6MWD) and number of repetitions were measured. Cardiorespiratory parameters, dyspnea and lower limb fatigue (Borg) were recorded before and after the tests. Results: Sit-to-stand repetitions (19 ± 6) and 6MWD (441 ± 104 m) were correlated (r = .716; P < .001). Good repeatability was found for STST and 6MWT. Good reliability was observed for STST (ICC = 0.902). Variations of heart rate and pulsed oxygen saturation were significantly different between these two tests (23% ± 17% vs 13% ± 11%; P = .022 and -7.6% ± 4.6% vs -0.7% ± 2.7%; P < .001 for 6MWT and STST, respectively). Variations of dyspnea and lower limb fatigue were similar between both tests (P = .827 and P = .467). Conclusion: The one minute sit-to-stand test is a valuable alternative to 6MWT to estimate functional exercise performance in COPD patients. The cardiorespiratory demand is different between both tests although the variation of dypsnea is similar. No learning effect was observed for STST
Fichier non déposé

Dates et versions

hal-03338346 , version 1 (08-09-2021)

Identifiants

Citer

Gregory Reychler, Eliott Boucard, Loïc Peran, Romain Pichon, Catherine Le Ber-Moy, et al.. One minute sit-to-stand test is an alternative to 6MWT to measure functional exercise performance in COPD patients. The Clinical Respiratory Journal, 2018, 12 (3), pp.1247-1256. ⟨10.1111/crj.12658⟩. ⟨hal-03338346⟩
19 Consultations
0 Téléchargements

Altmetric

Partager

More