Chapter 7: Operation and maintenance
Résumé
This chapter first provides information on general health and safety rules to be applied by operators in monitoring urban drainage and stormwater management (UDSM) systems, especially in the harsh confined environment of underground sewer systems. Second, it presents experience-based key recommendations for best practice and quality in operation, management and maintenance of sensors and installations for rainfall and discharge measurements. In the last part, three numerical methods (ordinary least squares, Williamson least squares, non-linear regression) are presented, with detailed examples of application, to establish calibration functions which are necessary for all sensors used in UDSM monitoring.