Impact of Enterovirus molecular assay turnaround time on hospitalization length during an Echovirus 30 Meningitis Outbreak, France, Fall 2014.
Résumé
Background: The impact of Enterovirus Real Time-Polymerase Chain Reaction assay (EV RT-PCR) on hospitalization lengths of patients with aseptic meningitis has been investigated but the impact of early EV RT-PCR results released on time before patient discharge remains unclear during Echovirus meningitis outbreaks.
Objective: To assess a potential correlation between EV RT-PCR turn-around time and hospitalization lengths during an Echovirus meningitis outbreak.
Method: Eighteen patients demonstrating a positive EV RT-PCR assay performed on Cerebrospinal Fluid (CSF) samples collected between October 1st 2014 and December 31st 2014 were retrospectively included. Viral protein 1 (VP1) gene region was amplified and sequenced using a classical Sanger sequencing reaction. Clinical data were retrospectively collected from patient’s records. Quantitative variables expressed as median values and ranges were compared using Mann Whitney U test. Correlations were performed using simple regression analysis.
Results: Phylogenetic VP1 sequence analyses identified that the outbreak was related to an Echovirus 30 strain in 7 out of the 10 cases with available sequencing data. The three remaining sequences analyses evidenced Echovirus 14, 9 and 7 strains. Hospitalization length was statistically shorter in children without comorbidity (n=5) than in adult patients (n=10) or neonates and children with comorbidity (n=3) (p=0.003 and 0.01 respectively), whereas EV RT-PCR turnaround time was not statistically different between these groups. Correlation between hospitalization length and EV RT-PCR turnaround time was poor (R2=0.06), especially in adults (R2=0.01)
Conclusion: Our data indicated that EV RT-PCR turnaround time was not correlated to hospitalization length during a short Echovirus meningitis outbreak.
Origine | Fichiers éditeurs autorisés sur une archive ouverte |
---|