Patella Distal Pole Fracture Treated Using Ipsilateral Hamstring Autograft Augmentation and No Additional Hardware - Archive ouverte HAL Access content directly
Journal Articles Arthroscopy Techniques Year : 2021

Patella Distal Pole Fracture Treated Using Ipsilateral Hamstring Autograft Augmentation and No Additional Hardware

Abstract

Patellar lower-pole fractures occur in relatively young patients after eccentric contraction of the quadriceps or direct trauma. Early diagnosis and adequate treatment lead to excellent outcomes and prevent tendon retraction and scarring. The aim of surgical treatment is to restore articular congruence and reestablish the extensor mechanism of the knee. All surgical treatments (sutures and tension band wiring, separate vertical wiring or augmented with Krackow sutures, wiring through screws, basket plate, hook plate) use additional hardware. We propose a hardware-free technique using ipsilateral hamstring augmentation.
Fichier principal
Vignette du fichier
PIIS2212628720302541.pdf (609.15 Ko) Télécharger le fichier
Origin Publication funded by an institution

Dates and versions

hal-03176995 , version 1 (23-03-2021)

Licence

Identifiers

Cite

Yassine Bulaïd, Sébastien Parratte, Jean-Noël Argenson, Matthieu Ollivier. Patella Distal Pole Fracture Treated Using Ipsilateral Hamstring Autograft Augmentation and No Additional Hardware. Arthroscopy Techniques, 2021, 10 (1), pp.e61-e65. ⟨10.1016/j.eats.2020.09.013⟩. ⟨hal-03176995⟩