Improvements in individual dose measurement techniques following nuclear emergencies - Archive ouverte HAL
Article Dans Une Revue Radioprotection Année : 2020

Improvements in individual dose measurement techniques following nuclear emergencies

Estelle Davesne
  • Fonction : Auteur
  • PersonId : 1071082
Didier Franck
  • Fonction : Auteur
  • PersonId : 1073260
James Marsh
  • Fonction : Auteur
PHE

Résumé

The aim of CONFIDENCE WP2 is to improve the situation awareness in the early phase of a nuclear accident by trying to reduce the uncertainty in individual dose assessment when dealing with external and internal exposures. Main WP2 research actions to improve external dosimetry in this emergency frame were the development of destruction-free protocols using electronic components in smartphones for external dose measurements, Monte Carlo (MCNP) calculations for organ dose assessment with associated uncertainties and the organization of a workshop for integration of biodosimetry into emergency response. On the other hand, one of the main concerns after the release of radioactive material in case of a nuclear reactor accident is the intake of radioiodines in workers and population. A smartphone/ tablet application for direct calculation of thyroid doses from monitoring data of the content of 131I (and 132I) in the thyroid was developed during the project (Prototype of processing unit for thyroid dose monitor [IDOSE]). Up to date age dependent ICRP dose per content values are used by this tool, allowing a rapid screening of exposed persons. A sensitivity analysis on thyroid doses was carried out, considering 16 exposure scenarios leading to 16 different dose estimates, using ICRP56/119 (ICRP60) vs. ICRP130/137 iodine models for adults, varying the time of intake, the time pattern (acute vs. chronic) and considering not well defined relative abundance of short-lived radioiodines and 132Te. Real cases of Europeans contaminated in Japan shortly after the Fukushima NPP accident (low doses), and artificial cases of high doses generated to see the impact of the different parameters in this study, were used for applying this multiintake scenario approach. Main conclusions of the study are presented here
Fichier principal
Vignette du fichier
0000170744_002.PDF (3.53 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03146200 , version 1 (18-02-2021)

Licence

Identifiants

Citer

Maria Antonia Lopez, Vladimir Berkovskyy, Gennadii Ratia, Cecile Challeton de Vathaire, Estelle Davesne, et al.. Improvements in individual dose measurement techniques following nuclear emergencies. Radioprotection, 2020, 55 (HS1), pp.S89-S93. ⟨10.1051/radiopro/2020017⟩. ⟨hal-03146200⟩
75 Consultations
108 Téléchargements

Altmetric

Partager

More