Six-minute walk test for individuals with schizophrenia
Résumé
Purpose: The six-minute walk test (6MWT) is a sub-maximal exercise test measuring the distance that a patient can walk quickly in a period of 6 minutes (6MWD). The objectives of this systematic review are to evaluate the 6MWT's suitability for measuring the impact of an intervention, to compare the 6MWD walked by patients with schizophrenia with data for the general population or matched controls, to identify the determinants of 6MWD and to examine the measurement properties and quality procedures of the 6MWT. Methods: Using five databases, we performed a systematic review of full-text articles published through August 2013. Results: Sixteen studies met our selection criteria. The assessment of the 6MWT's suitability for measuring the impact of interventions was not made because none of the interventional studies reported a significant increase in 6MWD. The distance walked by adults with schizophrenia seemed generally shorter than that walked by healthy adults. Mean 6MWDs ranged from 421 m to 648 m in the included studies. The 6MWD is usually negatively associated with a higher Body Mass Index, increased cigarette consumption, higher doses of antipsychotic medication and lower physical self-worth in individuals with schizophrenia. The 6MWT demonstrates high reliability. To date, however, its criterion validity has not been investigated. In spite of existing guidelines, the test procedures used in the studies reviewed varied significantly. Conclusions: Future physical health monitoring recommendations for patients with schizophrenia should include the 6MWT. Future studies should investigate its predictive role and continue to assess its measurement properties.