Résumé

In this paper, an innovative millimeter-wave (mm-wave) through-load switch for in-situ reflectometers and on-wafer calibration is proposed. This two-port device can switch between two states: (i) a through connection or (ii) a 50 Ω load for both of its ports. The through-load switch is composed of a 3-dB directional coupler and two nMOS transistors controlled through a biasing voltage applied to their gate. Measurement results of a 120-GHz 3-dB directional coupler are provided up to 145 GHz together with EM simulations and circuit-level simulations up to 220 GHz of the through-load switch. A wide bandwidth is obtained, from 73 GHz to 179 GHz, with limited insertion loss of 2 dB.
Fichier principal
Vignette du fichier
2020-NEWCAS2020_2.pdf (1.83 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-02958204 , version 1 (05-10-2020)

Licence

Identifiants

Citer

Marc Margalef-Rovira, Abdelhalim Saadi, Sylvain Bourdel, Manuel J. Barragan, Emmanuel Pistono, et al.. mm-Wave Through-Load Switch for in-situ Vector Network Analyzer on a 55-nm BiCMOS Technology. 18th IEEE International NEWCAS Conference (NEWCAS 2020), Jun 2020, Montreal, Canada. ⟨10.1109/NEWCAS49341.2020.9159829⟩. ⟨hal-02958204⟩