Transient performance of a magnetically geared induction machine
Résumé
The purpose of this paper is to investigate the transient performance of an induction machine coupled with a magnetic gear for industrial applications with low speed and high torque requirements. This new solution increases mechanical reliability and does not require maintenance and lubrication. The main objective is to study the direct-on-line starting ability of the electrical machine and its stability regarding a sudden variation of the load torque. A non-linear analytical model for the induction machine and the magnetic gear is first developed. The model is then linearized around an operating point to obtain the transfer function between the load angle and the electromagnetic torque from which an analytical expression for the mechanical resonant frequency is obtained. It is shown that the direct on-line starting is possible if the moment of inertia of the load is not greater than a maximum value.
Origine | Fichiers produits par l'(les) auteur(s) |
---|