Impact of environmental factors on in situ determination of iron in seawater by flow injection analysis - Archive ouverte HAL
Article Dans Une Revue Marine Chemistry Année : 2005

Impact of environmental factors on in situ determination of iron in seawater by flow injection analysis

Résumé

A sensitive method for iron determination in seawater has been adapted on a submersible chemical analyser for in situ measurements. The technique is based on flow injection analysis (FIA) coupled with spectrophotometric detection. When direct injection of seawater was used, the detection limit was 1.6 nM, and the precision 7%, for a triplicate injection of a 4 nM standard. At low iron concentrations, on line preconcentration using a column filled with 8-hydroxyquinoline (8HQ) resin was used. The detection limit was 0.15 nM (time of preconcentration = 240 s), and the precision 6%, for a triplicate determination of a 1 nM standard, allowing the determination of Fe in most of the oceanic regimes, except the most depleted surface waters. The effect of temperature, pressure, salinity, copper, manganese, and iron speciation on the response of the analyser was investigated. The slope of the calibration curves followed a linear relation as a function of pressure (C p = 2.8 Â 10 À 5 P + 3.4 Â 10 À 2 s nmol À 1 , R 2 = 0.997, for H = 13 8C) and an exponential relation as a function of temperature (C H = 0.009e 0.103H , R 2 = 0.832, for P = 3 bar). No statistical difference at 95% confidence level was observed for samples of different salinities (S = 0, 20, 35). Only very high concentration of copper (1000 Â [Fe]) produced a detectable interference. The chemical analyser was deployed in the coastal environment of the Bay of Brest to investigate the effect of iron speciation on the response of the analyser. Direct injection was used and seawater samples were acidified on line for 80 s. Dissolved iron (DFe, filtered seawater (0.4 Am), acidified and stored at pH 1.8) corresponded to 29 F 4% of Fe a (unfiltered seawater, acidified in line at pH 1.8 for 80 s). Most of Fe a (71 F 4%) was probably a fraction of total dissolvable iron (TDFe, unfiltered seawater, acidified and stored at pH 1.8).
Fichier principal
Vignette du fichier
publication-1209.pdf (433.25 Ko) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-02639226 , version 1 (06-01-2023)

Identifiants

Citer

Agathe Laës, Renaud Vuillemin, Bernard Leilde, Géraldine Sarthou, Bournot-Marec Claudie. Impact of environmental factors on in situ determination of iron in seawater by flow injection analysis. Marine Chemistry, 2005, 97 (3-4), pp.347-356. ⟨10.1016/j.marchem.2005.06.002⟩. ⟨hal-02639226⟩
153 Consultations
46 Téléchargements

Altmetric

Partager

More