Tracer diffusion of Cr in Ni and Ni-22Cr studied by SIMS - Archive ouverte HAL Access content directly
Journal Articles Materialia Year : 2018

Tracer diffusion of Cr in Ni and Ni-22Cr studied by SIMS

Abstract

The volume diffusion of Cr in Ni and in Ni-22Cr (at. %) was studied from tracer experiments, using 52Cr and 54Cr as tracers, in the temperature range 542-843 °C. Intensity-depth profiles were generated by secondary ion mass spectrometry (SIMS), which allowed data to be obtained at substantially lower temperatures than previously available. Chromium diffusion was found to be slightly slower in Ni-22Cr than in Ni, in agreement with literature data at high temperature. The mobility parameters (ln(D0) = −1.6±0.3 [cm 2 /s], Q = 260 ± 2 kJ/mol for Cr in Ni, and ln(D0) = −0.3 ± 1.3 [cm 2 /s], Q = 279 ± 10 kJ/mol for Cr in Ni-22Cr) are in the lower range of those obtained by previous investigators in similar alloys. The present results indicate that the vacancy-solute exchange mechanism in effect at high temperature does not change significantly at least down to 542 °C.
Fichier principal
Vignette du fichier
tracer1.pdf (478.14 Ko) Télécharger le fichier
Origin Files produced by the author(s)
Loading...

Dates and versions

hal-02350036 , version 1 (05-11-2019)

Licence

Identifiers

Cite

Thomas Gheno, François Jomard, Clara Desgranges, Laure Martinelli. Tracer diffusion of Cr in Ni and Ni-22Cr studied by SIMS. Materialia, 2018, 3, pp.145-152. ⟨10.1016/j.mtla.2018.08.004⟩. ⟨hal-02350036⟩
64 View
293 Download

Altmetric

Share

Gmail Mastodon Facebook X LinkedIn More