<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-02290296</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-02T23:20:21+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Simple and efficient thermal calibration for MEMS gyroscopes</title>
            <author role="aut">
              <persName>
                <forename type="first">Alexis</forename>
                <surname>Nez</surname>
              </persName>
              <idno type="halauthorid">1411411-0</idno>
              <affiliation ref="#struct-118112"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Laetitia</forename>
                <surname>Fradet</surname>
              </persName>
              <email type="md5">eb80a740d3b6002da6be63fe11d93a4e</email>
              <email type="domain">univ-poitiers.fr</email>
              <idno type="idhal" notation="string">laetitia-fradet</idno>
              <idno type="idhal" notation="numeric">177182</idno>
              <idno type="halauthorid" notation="string">9830-177182</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-9285-4307</idno>
              <idno type="IDREF">https://www.idref.fr/077617908</idno>
              <affiliation ref="#struct-398390"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Pierre</forename>
                <surname>Laguillaumie</surname>
              </persName>
              <email type="md5">960a6ec75669b1d6102ecb3c5e620386</email>
              <email type="domain">univ-poitiers.fr</email>
              <idno type="idhal" notation="numeric">1301954</idno>
              <idno type="halauthorid" notation="string">1653980-1301954</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-7386-3881</idno>
              <idno type="IDREF">https://www.idref.fr/124775713</idno>
              <idno type="VIAF">https://viaf.org/viaf/206138272</idno>
              <idno type="ISNI">http://isni.org/isni/0000000358411374</idno>
              <affiliation ref="#struct-398390"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Tony</forename>
                <surname>Monnet</surname>
              </persName>
              <email type="md5">a3dd73b14e09f5afb49d381478267816</email>
              <email type="domain">univ-poitiers.fr</email>
              <idno type="idhal" notation="string">tonymonnet</idno>
              <idno type="idhal" notation="numeric">1272664</idno>
              <idno type="halauthorid" notation="string">253183-1272664</idno>
              <idno type="ORCID">https://orcid.org/0000-0003-2942-2437</idno>
              <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=8l_D8gsAAAAJ</idno>
              <idno type="VIAF">https://viaf.org/viaf/152956746</idno>
              <idno type="ISNI">http://isni.org/isni/0000000102558989</idno>
              <idno type="IDREF">https://www.idref.fr/122271963</idno>
              <affiliation ref="#struct-398390"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Patrick</forename>
                <surname>Lacouture</surname>
              </persName>
              <email type="md5">faa5a99f3d0087fb0eebb82a62d77a74</email>
              <email type="domain">univ-poitiers.fr</email>
              <idno type="idhal" notation="numeric">942167</idno>
              <idno type="halauthorid" notation="string">714966-942167</idno>
              <idno type="IDREF">https://www.idref.fr/033320144</idno>
              <idno type="VIAF">https://viaf.org/viaf/227060862</idno>
              <idno type="ISNI">http://isni.org/isni/000000036466786X</idno>
              <affiliation ref="#struct-398390"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Cécile</forename>
                <surname>Boye</surname>
              </persName>
              <email type="md5">feaf4c3812df5f7e46b49985bd0ec2fd</email>
              <email type="domain">ensma.fr</email>
            </editor>
            <funder ref="#projanr-49611"/>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2019-09-17 15:17:23</date>
              <date type="whenModified">2025-10-06 09:50:10</date>
              <date type="whenReleased">2019-09-17 15:17:23</date>
              <date type="whenProduced">2018-05</date>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="149612">
                <persName>
                  <forename>Cécile</forename>
                  <surname>Boye</surname>
                </persName>
                <email type="md5">feaf4c3812df5f7e46b49985bd0ec2fd</email>
                <email type="domain">ensma.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-02290296</idno>
            <idno type="halUri">https://hal.science/hal-02290296</idno>
            <idno type="halBibtex">nez:hal-02290296</idno>
            <idno type="halRefHtml">&lt;i&gt;Medical Engineering &amp; Physics&lt;/i&gt;, 2018, 55, pp.60-67. &lt;a target="_blank" href="https://dx.doi.org/10.1016/j.medengphy.2018.03.002"&gt;&amp;#x27E8;10.1016/j.medengphy.2018.03.002&amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">Medical Engineering &amp; Physics, 2018, 55, pp.60-67. &amp;#x27E8;10.1016/j.medengphy.2018.03.002&amp;#x27E9;</idno>
            <availability status="restricted"/>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="CNRS">CNRS - Centre national de la recherche scientifique</idno>
            <idno type="stamp" n="UNIV-POITIERS">Université de Poitiers</idno>
            <idno type="stamp" n="ENSMA">Ecole Nationale Supérieure de Mécanique et d'Aérotechnique</idno>
            <idno type="stamp" n="TDS-MACS">Réseau de recherche en Théorie des Systèmes Distribués, Modélisation, Analyse et Contrôle des Systèmes</idno>
            <idno type="stamp" n="PPRIME">Institut PPRIME (P')</idno>
            <idno type="stamp" n="ANR">ANR</idno>
            <idno type="stamp" n="ISAE-ENSMA">École nationale supérieure de mécanique et d’aérotechnique</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="2">International</note>
            <note type="popular" n="0">No</note>
            <note type="peer" n="1">Yes</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Simple and efficient thermal calibration for MEMS gyroscopes</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Alexis</forename>
                    <surname>Nez</surname>
                  </persName>
                  <idno type="halauthorid">1411411-0</idno>
                  <affiliation ref="#struct-118112"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Laetitia</forename>
                    <surname>Fradet</surname>
                  </persName>
                  <email type="md5">eb80a740d3b6002da6be63fe11d93a4e</email>
                  <email type="domain">univ-poitiers.fr</email>
                  <idno type="idhal" notation="string">laetitia-fradet</idno>
                  <idno type="idhal" notation="numeric">177182</idno>
                  <idno type="halauthorid" notation="string">9830-177182</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-9285-4307</idno>
                  <idno type="IDREF">https://www.idref.fr/077617908</idno>
                  <affiliation ref="#struct-398390"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Pierre</forename>
                    <surname>Laguillaumie</surname>
                  </persName>
                  <email type="md5">960a6ec75669b1d6102ecb3c5e620386</email>
                  <email type="domain">univ-poitiers.fr</email>
                  <idno type="idhal" notation="numeric">1301954</idno>
                  <idno type="halauthorid" notation="string">1653980-1301954</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-7386-3881</idno>
                  <idno type="IDREF">https://www.idref.fr/124775713</idno>
                  <idno type="VIAF">https://viaf.org/viaf/206138272</idno>
                  <idno type="ISNI">http://isni.org/isni/0000000358411374</idno>
                  <affiliation ref="#struct-398390"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Tony</forename>
                    <surname>Monnet</surname>
                  </persName>
                  <email type="md5">a3dd73b14e09f5afb49d381478267816</email>
                  <email type="domain">univ-poitiers.fr</email>
                  <idno type="idhal" notation="string">tonymonnet</idno>
                  <idno type="idhal" notation="numeric">1272664</idno>
                  <idno type="halauthorid" notation="string">253183-1272664</idno>
                  <idno type="ORCID">https://orcid.org/0000-0003-2942-2437</idno>
                  <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=8l_D8gsAAAAJ</idno>
                  <idno type="VIAF">https://viaf.org/viaf/152956746</idno>
                  <idno type="ISNI">http://isni.org/isni/0000000102558989</idno>
                  <idno type="IDREF">https://www.idref.fr/122271963</idno>
                  <affiliation ref="#struct-398390"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Patrick</forename>
                    <surname>Lacouture</surname>
                  </persName>
                  <email type="md5">faa5a99f3d0087fb0eebb82a62d77a74</email>
                  <email type="domain">univ-poitiers.fr</email>
                  <idno type="idhal" notation="numeric">942167</idno>
                  <idno type="halauthorid" notation="string">714966-942167</idno>
                  <idno type="IDREF">https://www.idref.fr/033320144</idno>
                  <idno type="VIAF">https://viaf.org/viaf/227060862</idno>
                  <idno type="ISNI">http://isni.org/isni/000000036466786X</idno>
                  <affiliation ref="#struct-398390"/>
                </author>
              </analytic>
              <monogr>
                <idno type="halJournalId" status="VALID">16985</idno>
                <idno type="issn">1350-4533</idno>
                <idno type="eissn">1873-4030</idno>
                <title level="j">Medical Engineering &amp; Physics</title>
                <imprint>
                  <publisher>Elsevier</publisher>
                  <biblScope unit="volume">55</biblScope>
                  <biblScope unit="pp">60-67</biblScope>
                  <date type="datePub">2018-05</date>
                </imprint>
              </monogr>
              <idno type="doi">10.1016/j.medengphy.2018.03.002</idno>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="en">English</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="en">Measurement model</term>
                <term xml:lang="en">Thermal calibration</term>
                <term xml:lang="en">Gyroscope</term>
                <term xml:lang="en">Microelectromechanical system (MEMS)</term>
              </keywords>
              <classCode scheme="halDomain" n="phys.meca.mefl">Physics [physics]/Mechanics [physics]/Fluid mechanics [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="phys.meca.msmeca">Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="spi.acou">Engineering Sciences [physics]/Acoustics [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="spi.auto">Engineering Sciences [physics]/Automatic</classCode>
              <classCode scheme="halDomain" n="spi.elec">Engineering Sciences [physics]/Electromagnetism</classCode>
              <classCode scheme="halDomain" n="spi.fluid">Engineering Sciences [physics]/Reactive fluid environment</classCode>
              <classCode scheme="halDomain" n="spi.nrj">Engineering Sciences [physics]/Electric power</classCode>
              <classCode scheme="halDomain" n="phys.meca.ther">Physics [physics]/Mechanics [physics]/Thermics [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="phys.meca.vibr">Physics [physics]/Mechanics [physics]/Vibrations [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="phys.mphy">Physics [physics]/Mathematical Physics [math-ph]</classCode>
              <classCode scheme="halDomain" n="phys.qphy">Physics [physics]/Quantum Physics [quant-ph]</classCode>
              <classCode scheme="halDomain" n="phys.meca.acou">Physics [physics]/Mechanics [physics]/Acoustics [physics.class-ph]</classCode>
              <classCode scheme="halDomain" n="phys.meca.biom">Physics [physics]/Mechanics [physics]/Biomechanics [physics.med-ph]</classCode>
              <classCode scheme="halDomain" n="chim.mate">Chemical Sciences/Material chemistry</classCode>
              <classCode scheme="halDomain" n="chim.poly">Chemical Sciences/Polymers</classCode>
              <classCode scheme="halTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halOldTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halTreeTypology" n="ART">Journal articles</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>Gyroscopes are now becoming one of the most sold MEMS sensors, given that the many applications that require their use are booming. In the medical field, gyroscopes can be found in Inertial Measurement Units used for the development of clinical tools that are dedicated to human-movement monitoring. However, MEMS gyroscopes are known to suffer from a drift phenomenon, which is mainly due to temperature variations. This drift dramatically affects measurement capability, especially that of cheap MEMs gyroscopes. Calibration is therefore a key factor in achieving accurate measurements. However, traditional calibration procedures are often complex and require costly equipment. This paper therefore proposes an easy protocol for performing a thermal gyroscope calibration. In this protocol, accuracy over the angular velocity is evaluated by referring to an optoelectronic measurement, and is compared with the traditional calibration performed by the manufacturer. The RMSE between the reference angular velocity and that obtained with the proposed calibration was of 0.7°/s, which was slightly smaller than the RMSE of 1.1°/s achieved by the manufacturer's calibration. An analysis of uncertainty propagation shows that offset variability is the major source of error over the computed rate of rotation from the tested sensors, since it accounts for 97% of the error. It can be concluded that the proposed simple calibration method leads to a similar degree of accuracy as that achieved by the manufacturer's procedure.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-118112" status="VALID">
          <idno type="IdRef">16376297X</idno>
          <idno type="ISNI">0000000121643230</idno>
          <idno type="RNSR">201019365K</idno>
          <idno type="ROR">https://ror.org/05vjdsn22</idno>
          <idno type="Wikidata">Q3151798</idno>
          <orgName>Institut Pprime [UPR 3346]</orgName>
          <orgName type="acronym">PPrime [Poitiers]</orgName>
          <date type="start">2010-01-01</date>
          <desc>
            <address>
              <addrLine>11 boulevard Marie et Pierre Curie – Site du futuroscope – TSA 41123 – 86073 Poitiers Cedex 9 – France</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.pprime.fr/</ref>
          </desc>
          <listRelation>
            <relation name="UPR 3346" active="#struct-54493" type="direct"/>
            <relation name="UPR 3346" active="#struct-300463" type="direct"/>
            <relation name="UPR3346" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="researchteam" xml:id="struct-398390" status="VALID">
          <orgName>Robotique, Biomécanique, Sport, Santé [Institut Pprime]</orgName>
          <orgName type="acronym">RoBioSS</orgName>
          <date type="start">2010-01-01</date>
          <desc>
            <address>
              <addrLine>PPRIME Institut P' : Recherche et Ingénierie en Matériaux, Mécanique et Énergétique – 11 boulevard Marie et Pierre Curie – Site du futuroscope – TSA 41123 – 86073 Poitiers Cedex 9 – France</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://pprime.fr/la-recherche/genie-mecanique-systemes-complexes/robotique-biomecanique-sport-sante-robioss/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-555997" type="direct"/>
            <relation active="#struct-118112" type="indirect"/>
            <relation name="UPR 3346" active="#struct-54493" type="indirect"/>
            <relation name="UPR 3346" active="#struct-300463" type="indirect"/>
            <relation name="UPR3346" active="#struct-441569" type="indirect"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-54493" status="VALID">
          <idno type="IdRef">026403765</idno>
          <idno type="ISNI">0000000121606368</idno>
          <idno type="ROR">https://ror.org/04xhy8q59</idno>
          <idno type="Wikidata">Q661056</idno>
          <orgName>Université de Poitiers =  University of Poitiers</orgName>
          <orgName type="acronym">UP</orgName>
          <desc>
            <address>
              <addrLine>15, rue de l'Hôtel Dieu - 86034 Poitiers Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.univ-poitiers.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-300463" status="VALID">
          <idno type="IdRef">028024400</idno>
          <idno type="ROR">https://ror.org/04jx68594</idno>
          <orgName>École Nationale Supérieure de Mécanique et d’Aérotechnique [Poitiers]</orgName>
          <orgName type="acronym">ISAE-ENSMA</orgName>
          <desc>
            <address>
              <addrLine>Téléport 2 – 1 avenue Clément AderBP 4010986961 Futuroscope Chasseneuil Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.ensma.fr/</ref>
          </desc>
        </org>
        <org type="regroupinstitution" xml:id="struct-441569" status="VALID">
          <idno type="IdRef">02636817X</idno>
          <idno type="ISNI">0000000122597504</idno>
          <idno type="ROR">https://ror.org/02feahw73</idno>
          <orgName>Centre National de la Recherche Scientifique</orgName>
          <orgName type="acronym">CNRS</orgName>
          <date type="start">1939-10-19</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.cnrs.fr/</ref>
          </desc>
        </org>
        <org type="department" xml:id="struct-555997" status="VALID">
          <orgName>Département Génie Mécanique et Systèmes Complexes [Institut Pprime]</orgName>
          <orgName type="acronym">Département GMSC</orgName>
          <date type="start">2010-01-01</date>
          <desc>
            <address>
              <addrLine>11 boulevard Marie et Pierre Curie – Site du futuroscope – TSA 41123 – 86073 Poitiers Cedex 9 – France</addrLine>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation active="#struct-118112" type="direct"/>
            <relation name="UPR 3346" active="#struct-54493" type="indirect"/>
            <relation name="UPR 3346" active="#struct-300463" type="indirect"/>
            <relation name="UPR3346" active="#struct-441569" type="indirect"/>
          </listRelation>
        </org>
      </listOrg>
      <listOrg type="projects">
        <org type="anrProject" xml:id="projanr-49611" status="VALID">
          <idno type="anr">ANR-10-EQPX-0044</idno>
          <orgName>ROBOTEX</orgName>
          <desc>Réseau national de plateformes robotiques d'excellence</desc>
          <date type="start">2010</date>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>