Beam based measurements of relative RF phase - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2019

Beam based measurements of relative RF phase

Résumé

The ferrite loaded RF cavities of the CERN Proton Synchrotron Booster will be replaced with Finemet™ loaded cavities during Long Shutdown 2 (2019-2020). To fully realise the potential of the new cavities, the relative RF phases must be aligned along the acceleration ramp, where the revolution frequency changes by nearly a factor of 2. A beam based method of measuring the relative phase between the cavities is desired to give the best possible compensation for the frequency dependent phase shift. In this paper we present an operationally viable method to measure the phase shift as a function of RF frequency. The relative phase of the RF cavities can be aligned to within a few degrees, giving an error on the voltage seen by the beam of less than 1%.
Fichier non déposé

Dates et versions

hal-02277879 , version 1 (04-09-2019)

Identifiants

Citer

Simon Albright, Michal Kuczynski. Beam based measurements of relative RF phase. 10th International Particle Accelerator Conference, May 2019, Melbourne, Australia. pp.THPRB066, ⟨10.18429/JACoW-IPAC2019-THPRB066⟩. ⟨hal-02277879⟩