Experimental behaviour of high-performance concrete in confined tension
Résumé
Prestressed concrete is commonly used in a wide range of applications, yet on rare occasions spalling problems have been reported for concrete structures prestressed in two directions. The tensile behaviour of concrete may be affected by prestressing; consequently a number of experiments have been performed to reproduce this load combination on laboratory samples. Tests were carried out in a compression-tension triaxial cell suitable for the independent application of a lateral confining pressure, as well as a direct axial tension load. Results reveal a measurable but limited reduction in concrete tensile strength with a confining pressure of a similar magnitude as the prestress (order of magnitude of 10 MPa). Further experiments were conducted at higher confining pressures, in both confined tension and in triaxial extension, in order to generate an overview of limit state behaviour for the studied high performance concrete. © RILEM 2009.
Mots clés
Axial tensions
Concrete structures
Confining pressures
Experimental test
High-performance concrete
Lateral confining pressure
Limit state
Load combination
Order of magnitude
Pre-stress
Pre-stressed
Tensile behaviour
Triaxial cells
Triaxial extension
Prestressed concrete
Rock pressure
Tensile strength