Mass flow rate and permeability measurements in microporous media - Archive ouverte HAL
Article Dans Une Revue Vacuum Année : 2018

Mass flow rate and permeability measurements in microporous media

Résumé

10 The transient method of the mass flow rate measurements through a microp-orous media is developed and analyzed. This method is based on the constant volume technique and the exponential fit of the pressure evolution in each tank which allows calculating the permeability directly. The pressure relaxation time, a single fitting parameter, is introduced and its behaviors are analyzed in a large pressure range. By measuring the pressure relaxation time for one gas, the per-meability of a microporous sample can be derived for the other gases. With the actual experimental setup, we measured the mass flow rate through the micro-porous media in the range 5 · 10 −7 − 5 · 10 −12 [kg s −1 ] and the permeability in the range 10 −14 − 10 −11 [m 2 ].
Fichier principal
Vignette du fichier
perm_microporous_02.pdf (761.49 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01888007 , version 1 (08-03-2019)

Identifiants

Citer

Martin Victor Johansson, Fabrice Testa, Imen Zaier, Pierre Perrier, Jean Philippe Bonnet, et al.. Mass flow rate and permeability measurements in microporous media. Vacuum, 2018, 158, pp.75-85. ⟨10.1016/j.vacuum.2018.09.030⟩. ⟨hal-01888007⟩
128 Consultations
1165 Téléchargements

Altmetric

Partager

More