Detecting Flutter Waves in the Electrocardiogram Using Generalized Likelihood Ratio Test - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2018

Detecting Flutter Waves in the Electrocardiogram Using Generalized Likelihood Ratio Test

Résumé

Accurate detection of f waves during atrial flutter is difficult. However, f waves contain information on the pathology and are useful for non-invasive diagnosis. The setup and difficulties of f wave detection lends itself to the use of statistical signal detection techniques. Real-life constraints can be modeled in the signal observation using several parameters in order to produce signal detectors with good performance. Several detectors were developed and tested using real 12-lead ECG recordings with manually annotated f wave markers available. At the end, a simple detector is obtained with relatively good detection performance (AUC = 0.89, (Se, Sp) = (0.87, 0.76)) and a threshold is available for use in automatic detection of f waves.
Fichier principal
Vignette du fichier
cinc2018_paper2.pdf (205.17 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01883581 , version 1 (28-09-2018)

Identifiants

  • HAL Id : hal-01883581 , version 1

Citer

Muhammad Haziq Azman, Olivier Meste, Kushsairy Kadir. Detecting Flutter Waves in the Electrocardiogram Using Generalized Likelihood Ratio Test. Computing in Cardiology, Sep 2018, Maastricht, Netherlands. ⟨hal-01883581⟩
150 Consultations
157 Téléchargements

Partager

Gmail Facebook X LinkedIn More