<?xml version="1.0" encoding="utf-8"?>
<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-01688875</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-20T09:23:47+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="fr">La compatibilité en électronique de puissance</title>
            <author role="aut">
              <persName>
                <forename type="first">François</forename>
                <surname>Costa</surname>
              </persName>
              <email type="md5">ff72ddab74f42e2fcb2caecca236d70e</email>
              <email type="domain">satie.ens-cachan.fr</email>
              <idno type="idhal" notation="string">francois-costa</idno>
              <idno type="idhal" notation="numeric">16852</idno>
              <idno type="halauthorid" notation="string">4254-16852</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-0303-6346</idno>
              <idno type="IDREF">https://www.idref.fr/070832781</idno>
              <affiliation ref="#struct-1194"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Cyrille</forename>
                <surname>Gautier</surname>
              </persName>
              <email type="md5">8dd4b8f3cca5f15166b4973ca84e839a</email>
              <email type="domain">safrangroup.com</email>
              <idno type="idhal" notation="string">cyrille-gautier</idno>
              <idno type="idhal" notation="numeric">766442</idno>
              <idno type="halauthorid" notation="string">284478-766442</idno>
              <idno type="ORCID">https://orcid.org/0000-0001-8925-5314</idno>
              <affiliation ref="#struct-1194"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Eric</forename>
                <surname>Labouré</surname>
              </persName>
              <email type="md5">203b757dbd72c3baf5edd368ee78ecdb</email>
              <email type="domain">geeps.centralesupelec.fr</email>
              <idno type="idhal" notation="string">eric-laboure</idno>
              <idno type="idhal" notation="numeric">173480</idno>
              <idno type="halauthorid" notation="string">28027-173480</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-4343-834X</idno>
              <idno type="IDREF">https://www.idref.fr/160358280</idno>
              <affiliation ref="#struct-1290"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Bertrand</forename>
                <surname>Revol</surname>
              </persName>
              <email type="md5">b4db7464acd26fa9b048ca16e5215035</email>
              <email type="domain">safrangroup.com</email>
              <idno type="idhal" notation="string">bertrand-revol</idno>
              <idno type="idhal" notation="numeric">15787</idno>
              <idno type="halauthorid" notation="string">5505-15787</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-6068-5086</idno>
              <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=HoevOUYAAAAJ&amp;hl=fr</idno>
              <idno type="IDREF">https://www.idref.fr/076553302</idno>
              <affiliation ref="#struct-1194"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Bertrand</forename>
                <surname>Revol</surname>
              </persName>
              <email type="md5">b4db7464acd26fa9b048ca16e5215035</email>
              <email type="domain">safrangroup.com</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2018-01-19 18:17:50</date>
              <date type="whenWritten">2013</date>
              <date type="whenModified">2025-04-14 11:44:04</date>
              <date type="whenReleased">2018-01-19 18:17:50</date>
              <date type="whenProduced">2013</date>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="122966">
                <persName>
                  <forename>Bertrand</forename>
                  <surname>Revol</surname>
                </persName>
                <email type="md5">b4db7464acd26fa9b048ca16e5215035</email>
                <email type="domain">safrangroup.com</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-01688875</idno>
            <idno type="halUri">https://hal.science/hal-01688875</idno>
            <idno type="halBibtex">costa:hal-01688875</idno>
            <idno type="halRefHtml">Hermes Science. Lavoisier, 2013, Sciences et Technologies de l'Energie Electrique, Bernard Multon, 978-2-7462-4575-4</idno>
            <idno type="halRef">Hermes Science. Lavoisier, 2013, Sciences et Technologies de l'Energie Electrique, Bernard Multon, 978-2-7462-4575-4</idno>
            <availability status="restricted"/>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="SUPELEC">SUPELEC</idno>
            <idno type="stamp" n="UPMC" corresp="SORBONNE-UNIVERSITE">Université Pierre et Marie Curie</idno>
            <idno type="stamp" n="EC-PARIS">Ecole Centrale Paris</idno>
            <idno type="stamp" n="CNRS">CNRS - Centre national de la recherche scientifique</idno>
            <idno type="stamp" n="UNIV-CERGY">Université de Cergy Pontoise</idno>
            <idno type="stamp" n="UNIV-PSUD">Université Paris Sud - Paris XI</idno>
            <idno type="stamp" n="ENS-CACHAN">Ecole Normale Supérieure de Cachan</idno>
            <idno type="stamp" n="CNAM">Conservatoire National des Arts et Métiers</idno>
            <idno type="stamp" n="SUP_LGEP" corresp="SUPELEC">Laboratoire de génie électrique de Paris</idno>
            <idno type="stamp" n="SUP_ICHAMS" corresp="SUPELEC">ICHAMS - Equipe Interaction Champs - Matériaux et Structures</idno>
            <idno type="stamp" n="SATIE" corresp="UNIV-CERGY">Systèmes et Applications des Technologies de l'Information et de l'Energie</idno>
            <idno type="stamp" n="IFSTTAR">Ifsttar</idno>
            <idno type="stamp" n="GEEPS" corresp="SORBONNE-UNIVERSITE">Laboratoire Génie électrique et électronique de Paris</idno>
            <idno type="stamp" n="ECO2" corresp="GEEPS">Pôle Systèmes</idno>
            <idno type="stamp" n="UNIV-PARIS-SACLAY">Université Paris-Saclay</idno>
            <idno type="stamp" n="UNIV-PSUD-SACLAY" corresp="UNIV-PARIS-SACLAY">Université Paris Sud pour Paris Saclay</idno>
            <idno type="stamp" n="UPMC_POLE_1" corresp="UPMC">UPMC Pôle 1</idno>
            <idno type="stamp" n="SATIE-CSEE" corresp="SATIE">Pôle CSEE - SATIE</idno>
            <idno type="stamp" n="UNIV-RENNES">Université de Rennes</idno>
            <idno type="stamp" n="SORBONNE-UNIVERSITE">Sorbonne Université</idno>
            <idno type="stamp" n="SU-SCIENCES" corresp="SORBONNE-UNIVERSITE">Faculté des Sciences de Sorbonne Université</idno>
            <idno type="stamp" n="CY-TECH-SE" corresp="UNIV-CERGY">CY TECH : Sciences expérimentales</idno>
            <idno type="stamp" n="FARMAN">Institut Farman</idno>
            <idno type="stamp" n="ENS-PARIS-SACLAY">Ecole Normale Supérieure paris-Saclay</idno>
            <idno type="stamp" n="ALLIANCE-SU"> Alliance Sorbonne Université</idno>
            <idno type="stamp" n="UNIV-EIFFEL">Université Gustave Eiffel</idno>
            <idno type="stamp" n="IFSTTAR-UNIVEIFFEL">Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux</idno>
            <idno type="stamp" n="TEST3-HALCNRS">TEST3-HALCNRS</idno>
            <idno type="stamp" n="HESAM-CNAM" corresp="HESAM">Conservatoire National des Arts et Métiers - Hesam</idno>
            <idno type="stamp" n="HESAM">Hesam</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="2">International</note>
            <note type="popular" n="0">No</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="fr">La compatibilité en électronique de puissance</title>
                <author role="aut">
                  <persName>
                    <forename type="first">François</forename>
                    <surname>Costa</surname>
                  </persName>
                  <email type="md5">ff72ddab74f42e2fcb2caecca236d70e</email>
                  <email type="domain">satie.ens-cachan.fr</email>
                  <idno type="idhal" notation="string">francois-costa</idno>
                  <idno type="idhal" notation="numeric">16852</idno>
                  <idno type="halauthorid" notation="string">4254-16852</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-0303-6346</idno>
                  <idno type="IDREF">https://www.idref.fr/070832781</idno>
                  <affiliation ref="#struct-1194"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Cyrille</forename>
                    <surname>Gautier</surname>
                  </persName>
                  <email type="md5">8dd4b8f3cca5f15166b4973ca84e839a</email>
                  <email type="domain">safrangroup.com</email>
                  <idno type="idhal" notation="string">cyrille-gautier</idno>
                  <idno type="idhal" notation="numeric">766442</idno>
                  <idno type="halauthorid" notation="string">284478-766442</idno>
                  <idno type="ORCID">https://orcid.org/0000-0001-8925-5314</idno>
                  <affiliation ref="#struct-1194"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Eric</forename>
                    <surname>Labouré</surname>
                  </persName>
                  <email type="md5">203b757dbd72c3baf5edd368ee78ecdb</email>
                  <email type="domain">geeps.centralesupelec.fr</email>
                  <idno type="idhal" notation="string">eric-laboure</idno>
                  <idno type="idhal" notation="numeric">173480</idno>
                  <idno type="halauthorid" notation="string">28027-173480</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-4343-834X</idno>
                  <idno type="IDREF">https://www.idref.fr/160358280</idno>
                  <affiliation ref="#struct-1290"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Bertrand</forename>
                    <surname>Revol</surname>
                  </persName>
                  <email type="md5">b4db7464acd26fa9b048ca16e5215035</email>
                  <email type="domain">safrangroup.com</email>
                  <idno type="idhal" notation="string">bertrand-revol</idno>
                  <idno type="idhal" notation="numeric">15787</idno>
                  <idno type="halauthorid" notation="string">5505-15787</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-6068-5086</idno>
                  <idno type="GOOGLE SCHOLAR">https://scholar.google.fr/citations?user=HoevOUYAAAAJ&amp;hl=fr</idno>
                  <idno type="IDREF">https://www.idref.fr/076553302</idno>
                  <affiliation ref="#struct-1194"/>
                </author>
              </analytic>
              <monogr>
                <idno type="isbn">978-2-7462-4575-4</idno>
                <editor>Hermes Science</editor>
                <imprint>
                  <publisher>Lavoisier</publisher>
                  <biblScope unit="serie">Sciences et Technologies de l'Energie Electrique</biblScope>
                  <date type="datePub">2013</date>
                </imprint>
              </monogr>
              <series>
                <editor>Bernard Multon</editor>
              </series>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="fr">French</language>
            </langUsage>
            <textClass>
              <classCode scheme="halDomain" n="spi.nrj">Engineering Sciences [physics]/Electric power</classCode>
              <classCode scheme="halTypology" n="OUV">Books</classCode>
              <classCode scheme="halOldTypology" n="OUV">Books</classCode>
              <classCode scheme="halTreeTypology" n="OUV">Books</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>La demande croissante d'énergie électrique dans les transports terrestre et aérien conduit à utiliser massivement des équipements basés sur l'électronique de puissance. Les progrès sur les semiconducteurs de puissance, technologie au coeur de ces dispositifs, permettent d'accroître fortement leur densité volumique d'énergie avec un excellent rendement. Toutefois, la forte dissémination de ces techniques, la montée en fréquence et en vitesse de commutation des semiconducteurs conduisent à une augmentation importante de la pollution électromagnétique qu'ils produisent. Les phénomènes de compatibilité électromagnétique en électronique de puissance sont traités et illustrés par des cas concrets issus des applications industrielles. Partant du concept de cellule de commutation, les émissions de perturbations électromagnétiques sont expliquées, modélisées, puis l'approche est généralisée pour des systèmes plus complexes. Enfin, les moyens spécifiques de réduction des phénomènes parasites sont exposés, plus particulièrement les aspects liés à l'électronique de puissance, au filtrage et au blindage.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-1194" status="OLD">
          <idno type="IdRef">155499165</idno>
          <idno type="RNSR">200212702C</idno>
          <orgName>Systèmes et Applications des Technologies de l'Information et de l'Energie</orgName>
          <orgName type="acronym">SATIE</orgName>
          <date type="start">2002-01-01</date>
          <date type="end">2019-10-28</date>
          <desc>
            <address>
              <addrLine>61 av du President Wilson 94235 CACHAN Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.satie.ens-cachan.fr</ref>
          </desc>
          <listRelation>
            <relation active="#struct-6862" type="direct"/>
            <relation active="#struct-92966" type="direct"/>
            <relation active="#struct-222110" type="direct"/>
            <relation active="#struct-247362" type="direct"/>
            <relation name="UMR CNRS 8029" active="#struct-300305" type="direct"/>
            <relation active="#struct-531928" type="indirect"/>
            <relation name="UMR8029" active="#struct-300351" type="direct"/>
            <relation name="UMR8029" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-1290" status="OLD">
          <orgName>Laboratoire de génie électrique de Paris</orgName>
          <orgName type="acronym">LGEP</orgName>
          <desc>
            <address>
              <addrLine>11 rue Joliot Curie Plateau de Moulon 91192 GIF SUR YVETTE CEDEX</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.lgep.supelec.fr</ref>
          </desc>
          <listRelation>
            <relation active="#struct-92966" type="direct"/>
            <relation active="#struct-93591" type="direct"/>
            <relation active="#struct-303397" type="direct"/>
            <relation name="UMR8507" active="#struct-441569" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-6862" status="VALID">
          <orgName>École normale supérieure - Cachan</orgName>
          <orgName type="acronym">ENS Cachan</orgName>
          <desc>
            <address>
              <addrLine>61, avenue du Président Wilson - 94230 Cachan</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ens-cachan.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-92966" status="OLD">
          <idno type="ROR">https://ror.org/028rypz17</idno>
          <orgName>Université Paris-Sud - Paris 11</orgName>
          <orgName type="acronym">UP11</orgName>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <addrLine>Bâtiment 300 - 91405 Orsay cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.u-psud.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-222110" status="OLD">
          <idno type="ROR">https://ror.org/02xwvzv71</idno>
          <orgName>Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux</orgName>
          <orgName type="acronym">IFSTTAR</orgName>
          <date type="start">2011-01-01</date>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <addrLine>14-20 Boulevard Newton - Cité Descartes, Champs sur Marne - F-77447 Marne la Vallée Cedex 2</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ifsttar.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-247362" status="VALID">
          <idno type="ROR">https://ror.org/03rxtdc22</idno>
          <orgName>École normale supérieure - Rennes</orgName>
          <orgName type="acronym">ENS Rennes</orgName>
          <desc>
            <address>
              <addrLine>Campus de Ker Lann - avenue Robert Schuman - 35170 Bruz</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.ens-rennes.fr</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-300305" status="OLD">
          <idno type="IdRef">03463486X</idno>
          <idno type="ROR">https://ror.org/03vs46t66</idno>
          <orgName>Université de Cergy Pontoise</orgName>
          <orgName type="acronym">UCP</orgName>
          <date type="start">1991-07-22</date>
          <date type="end">2019-10-29</date>
          <desc>
            <address>
              <addrLine>33 Boulevard du Port, 95011 Cergy-Pontoise Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.u-cergy.fr/</ref>
          </desc>
          <listRelation>
            <relation active="#struct-531928" type="direct"/>
          </listRelation>
        </org>
        <org type="regroupinstitution" xml:id="struct-531928" status="OLD">
          <idno type="IdRef">203111508</idno>
          <idno type="ROR">https://ror.org/0033vhx30</idno>
          <orgName>Université Paris-Seine</orgName>
          <date type="start">2015-02-13</date>
          <date type="end">2019-10-29</date>
          <desc>
            <address>
              <addrLine>3 avenue Bernard Hirsch, CS 50105, 95021 Cergy-Pontoise</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.universiteparisseine.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-300351" status="VALID">
          <idno type="IdRef">027404978</idno>
          <idno type="ISNI">0000000121690459</idno>
          <idno type="ROR">https://ror.org/0175hh227</idno>
          <orgName>Conservatoire National des Arts et Métiers [Cnam]</orgName>
          <orgName type="acronym">Cnam</orgName>
          <desc>
            <address>
              <addrLine>292 Rue Saint-Martin, 75003 Paris</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.cnam.fr/</ref>
          </desc>
        </org>
        <org type="regroupinstitution" xml:id="struct-441569" status="VALID">
          <idno type="IdRef">02636817X</idno>
          <idno type="ISNI">0000000122597504</idno>
          <idno type="ROR">https://ror.org/02feahw73</idno>
          <orgName>Centre National de la Recherche Scientifique</orgName>
          <orgName type="acronym">CNRS</orgName>
          <date type="start">1939-10-19</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.cnrs.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-93591" status="OLD">
          <idno type="ROR">https://ror.org/02en5vm52</idno>
          <orgName>Université Pierre et Marie Curie - Paris 6</orgName>
          <orgName type="acronym">UPMC</orgName>
          <date type="end">2017-12-31</date>
          <desc>
            <address>
              <addrLine>4 place Jussieu - 75005 Paris</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.upmc.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-303397" status="VALID">
          <orgName>Ecole Supérieure d'Electricité - SUPELEC (FRANCE)</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>