proFIA: A data preprocessing workflow for Flow Injection Analysis coupled to High-Resolution Mass Spectrometry - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Bioinformatics Année : 2017

proFIA: A data preprocessing workflow for Flow Injection Analysis coupled to High-Resolution Mass Spectrometry

Résumé

Motivation: Flow Injection Analysis coupled to High-Resolution Mass Spectrometry (FIA-HRMS) is a promising approach for high-throughput metabolomics. FIA-HRMS data, however, cannot be preprocessed with current software tools which rely on liquid chromatography separation, or handle low resolution data only. Results: We thus developed the proFIA package, which implements a suite of innovative algorithms to preprocess FIA-HRMS raw files, and generates the table of peak intensities. The workflow consists of 3 steps: i) noise estimation, peak detection and quantification, ii) peak grouping across samples, and iii) missing value imputation. In addition, we have implemented a new indicator to quantify the potential alteration of the feature peak shape due to matrix effect. The preprocessing is fast (less than 15 s per file), and the value of the main parameters (ppm and dmz) can be easily inferred from the mass resolution of the instrument. Application to two metabolomics datasets (including spiked serum samples) showed high precision (96%) and recall (98%) compared with manual integration. These results demonstrate that proFIA achieves very efficient and robust detection and quantification of FIA-HRMS data, and opens new opportunities for high-throughput phenotyping. Availability: The proFIA software (as well as the plasFIA data set) is available as an R package on the Bioconductor repository (http://bioconductor.org/packages/proFIA), and as a Galaxy module on the Main Toolshed (https://toolshed.g2.bx.psu.edu/) and on the Workflow4Metabolomics online infrastructure (http://workflow4metabolomics.org). Contacts: alexis.delabriere@cea.fr and etienne.thevenot@cea.fr.
Fichier principal
Vignette du fichier
DelabriereEtAl_2017_proFIA_Bioinformatics.pdf (2.02 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-01574347 , version 1 (13-08-2017)

Identifiants

Citer

Alexis Delabrière, Ulli A Hohenester, Benoit A Colsch, Christophe A Junot, François A Fenaille, et al.. proFIA: A data preprocessing workflow for Flow Injection Analysis coupled to High-Resolution Mass Spectrometry. Bioinformatics, 2017, 33 (23), pp.3767-3775. ⟨10.1093/bioinformatics/btx458⟩. ⟨hal-01574347⟩
182 Consultations
285 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More