A Multi-Channel Setup to Study Fractures in Scintillators - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Measur.Sci.Tech. Année : 2016

A Multi-Channel Setup to Study Fractures in Scintillators

C. Bouard
  • Fonction : Auteur
R. Briche
  • Fonction : Auteur
B. Manier
  • Fonction : Auteur
N. Zaïm
L. Vanel
P.C.F. Di Stefano
  • Fonction : Auteur

Résumé

To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the acoustic emission. Emitted visible light is recorded with nanosecond resolution, and crack propagation is monitored using infrared lighting and camera. An example of application to $\text{B}{{\text{i}}_{4}}\text{G}{{\text{e}}_{3}}{{\text{O}}_{12}}$ (BGO) is provided.

Dates et versions

hal-01553952 , version 1 (03-07-2017)

Identifiants

Citer

A. Tantot, C. Bouard, R. Briche, G. Lefèvre, B. Manier, et al.. A Multi-Channel Setup to Study Fractures in Scintillators. Measur.Sci.Tech., 2016, 27 (12), pp.125601. ⟨10.1088/0957-0233/27/12/125601⟩. ⟨hal-01553952⟩
71 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More