Unified behavior of soot production and radiative heat transfer in ethylene, propane and butane axisymmetric laminar diffusion flames at different oxygen indices
Résumé
An experimental study was conducted to investigate the effects of oxygen index on the flame geometry, soot production and radiative loss in laminar over-ventilated co-flow buoyant axisymmetric diffusion flames at atmospheric pressure. Three gaseous hydrocarbon fuels, namely ethylene, propane, and butane, were considered. The oxygen index was varied from 21% to 37% and several mass flow rates were used. These conditions were chosen to keep the flames under the smoke point. Soot volume fraction and temperature were deduced from line-of-sight attenuation and two-color emission measurements, respectively. A scaling analysis based on the smoke point height was developed in order to unify the sooting behavior of the flames investigated. This analysis produced correlations for the flame height, the maximum soot volume fraction, the maximum integrated soot volume fraction and the radiant fraction at the smoke point. Crown Copyright (C) 2016 Published by Elsevier Ltd. All rights reserved.