Assessment of respiratory activity during surface-mould cheese ripening - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Journal of Food Engineering Année : 2008

Assessment of respiratory activity during surface-mould cheese ripening

Résumé

The present study deals with the respiratory activity of the microbial consortia established on surface-mould cheese. A software sensor was developed, from a model linking the operating conditions established in the ripening room (temperature, relative humidity, carbon dioxide and oxygen concentration) to the cheese mass dynamic. It estimated the respiratory activity of the microbial consortia based on mass measurement only, without atmospheric gas composition sensors or off-line measurements. After some simplifications of the model, this observer can be seen as an integral Luenberger observer, with analytically defined gain values. This approach was validated on two ripening trials. Relative errors between estimated and calculated (from carbon dioxide and oxygen concentration measurements) respiratory activity were equal to 3.02% and 8.83% for Run 1 and Run 2, respectively.

Dates et versions

hal-01313359 , version 1 (09-05-2016)

Identifiants

Citer

Arnaud Helias, Ioan-Cristian Trelea, Georges Corrieu. Assessment of respiratory activity during surface-mould cheese ripening. Journal of Food Engineering, 2008, 85 (4), pp.632-638. ⟨10.1016/j.jfoodeng.2007.09.001⟩. ⟨hal-01313359⟩
59 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More