<TEI xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:hal="http://hal.archives-ouvertes.fr/" xmlns:gml="http://www.opengis.net/gml/3.3/" xmlns:gmlce="http://www.opengis.net/gml/3.3/ce" version="1.1" xsi:schemaLocation="http://www.tei-c.org/ns/1.0 http://api.archives-ouvertes.fr/documents/aofr-sword.xsd">
  <teiHeader>
    <fileDesc>
      <titleStmt>
        <title>HAL TEI export of hal-01259767</title>
      </titleStmt>
      <publicationStmt>
        <distributor>CCSD</distributor>
        <availability status="restricted">
          <licence target="https://creativecommons.org/publicdomain/zero/1.0/">CC0 1.0 - Universal</licence>
        </availability>
        <date when="2026-05-03T07:14:38+02:00"/>
      </publicationStmt>
      <sourceDesc>
        <p part="N">HAL API Platform</p>
      </sourceDesc>
    </fileDesc>
  </teiHeader>
  <text>
    <body>
      <listBibl>
        <biblFull>
          <titleStmt>
            <title xml:lang="en">Fault Tolerant MPC Design for Reliable Microgrid Energy Management under Uncertainties</title>
            <author role="aut">
              <persName>
                <forename type="first">Ionela</forename>
                <surname>Prodan</surname>
              </persName>
              <email type="md5">df0d7608933d2929fa6f896c8ec521b4</email>
              <email type="domain">lcis.grenoble-inp.fr</email>
              <idno type="idhal" notation="string">ionela-prodan</idno>
              <idno type="idhal" notation="numeric">2795</idno>
              <idno type="halauthorid" notation="string">11512-2795</idno>
              <idno type="IDREF">https://www.idref.fr/166887579</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-3522-5192</idno>
              <affiliation ref="#struct-25697"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Enrico</forename>
                <surname>Zio</surname>
              </persName>
              <email type="md5">6903b8a346d2c362e76b753cebd3cc31</email>
              <email type="domain">polimi.it</email>
              <idno type="idhal" notation="string">enrico-zio</idno>
              <idno type="idhal" notation="numeric">7318</idno>
              <idno type="halauthorid" notation="string">26319-7318</idno>
              <idno type="ORCID">https://orcid.org/0000-0002-7108-637X</idno>
              <idno type="IDREF">https://www.idref.fr/11103096X</idno>
              <affiliation ref="#struct-161195"/>
            </author>
            <author role="aut">
              <persName>
                <forename type="first">Florin</forename>
                <surname>Stoican</surname>
              </persName>
              <idno type="halauthorid">384512-0</idno>
              <affiliation ref="#struct-524560"/>
            </author>
            <editor role="depositor">
              <persName>
                <forename>Yanfu</forename>
                <surname>Li</surname>
              </persName>
              <email type="md5">fae9b99d629a315344fcf43f2f343539</email>
              <email type="domain">supelec.fr</email>
            </editor>
          </titleStmt>
          <editionStmt>
            <edition n="v1" type="current">
              <date type="whenSubmitted">2016-01-20 21:55:46</date>
              <date type="whenModified">2026-03-22 10:32:27</date>
              <date type="whenReleased">2016-01-21 09:49:19</date>
              <date type="whenProduced">2015-11</date>
              <date type="whenEndEmbargoed">2016-01-20</date>
              <ref type="file" target="https://hal.science/hal-01259767v1/document">
                <date notBefore="2016-01-20"/>
              </ref>
              <ref type="file" subtype="author" n="1" target="https://hal.science/hal-01259767v1/file/IP_microgrid_Energy_3.08.2015_.pdf" id="file-1259767-1338961">
                <date notBefore="2016-01-20"/>
              </ref>
            </edition>
            <respStmt>
              <resp>contributor</resp>
              <name key="163523">
                <persName>
                  <forename>Yanfu</forename>
                  <surname>Li</surname>
                </persName>
                <email type="md5">fae9b99d629a315344fcf43f2f343539</email>
                <email type="domain">supelec.fr</email>
              </name>
            </respStmt>
          </editionStmt>
          <publicationStmt>
            <distributor>CCSD</distributor>
            <idno type="halId">hal-01259767</idno>
            <idno type="halUri">https://hal.science/hal-01259767</idno>
            <idno type="halBibtex">prodan:hal-01259767</idno>
            <idno type="halRefHtml">&lt;i&gt;Energy&lt;/i&gt;, 2015, 91, pp.20-34. &lt;a target="_blank" href="https://dx.doi.org/10.1016/j.energy.2015.08.009"&gt;&amp;#x27E8;10.1016/j.energy.2015.08.009&amp;#x27E9;&lt;/a&gt;</idno>
            <idno type="halRef">Energy, 2015, 91, pp.20-34. &amp;#x27E8;10.1016/j.energy.2015.08.009&amp;#x27E9;</idno>
            <availability status="restricted">
              <licence target="https://about.hal.science/hal-authorisation-v1/">HAL Authorization<ref corresp="#file-1259767-1338961"/></licence>
            </availability>
          </publicationStmt>
          <seriesStmt>
            <idno type="stamp" n="UGA">HAL Grenoble Alpes</idno>
            <idno type="stamp" n="UNIV-PMF_GRENOBLE">Université Pierre-Mendès-France - Grenoble II</idno>
            <idno type="stamp" n="INPG">Institut polytechnique de Grenoble</idno>
            <idno type="stamp" n="LGI">Laboratoire Génie Industriel</idno>
            <idno type="stamp" n="LCIS">Laboratoire de Conception et d'Intégration des Systèmes</idno>
            <idno type="stamp" n="CENTRALESUPELEC">Ecole CentraleSupélec</idno>
            <idno type="stamp" n="LGI-SR" corresp="LGI">Equipe : Sureté et Risques</idno>
            <idno type="stamp" n="UNIV-PARIS-SACLAY">Université Paris-Saclay</idno>
            <idno type="stamp" n="CENTRALESUPELEC-SACLAY" corresp="UNIV-PARIS-SACLAY">CENTRALESUPELEC-SACLAY</idno>
            <idno type="stamp" n="EDF">EDF</idno>
            <idno type="stamp" n="GS-ENGINEERING">Graduate School Sciences de l'Ingénierie et des Systèmes</idno>
            <idno type="stamp" n="TEST-UGA">TEST-UGA</idno>
          </seriesStmt>
          <notesStmt>
            <note type="audience" n="2">International</note>
            <note type="popular" n="0">No</note>
            <note type="peer" n="1">Yes</note>
          </notesStmt>
          <sourceDesc>
            <biblStruct>
              <analytic>
                <title xml:lang="en">Fault Tolerant MPC Design for Reliable Microgrid Energy Management under Uncertainties</title>
                <author role="aut">
                  <persName>
                    <forename type="first">Ionela</forename>
                    <surname>Prodan</surname>
                  </persName>
                  <email type="md5">df0d7608933d2929fa6f896c8ec521b4</email>
                  <email type="domain">lcis.grenoble-inp.fr</email>
                  <idno type="idhal" notation="string">ionela-prodan</idno>
                  <idno type="idhal" notation="numeric">2795</idno>
                  <idno type="halauthorid" notation="string">11512-2795</idno>
                  <idno type="IDREF">https://www.idref.fr/166887579</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-3522-5192</idno>
                  <affiliation ref="#struct-25697"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Enrico</forename>
                    <surname>Zio</surname>
                  </persName>
                  <email type="md5">6903b8a346d2c362e76b753cebd3cc31</email>
                  <email type="domain">polimi.it</email>
                  <idno type="idhal" notation="string">enrico-zio</idno>
                  <idno type="idhal" notation="numeric">7318</idno>
                  <idno type="halauthorid" notation="string">26319-7318</idno>
                  <idno type="ORCID">https://orcid.org/0000-0002-7108-637X</idno>
                  <idno type="IDREF">https://www.idref.fr/11103096X</idno>
                  <affiliation ref="#struct-161195"/>
                </author>
                <author role="aut">
                  <persName>
                    <forename type="first">Florin</forename>
                    <surname>Stoican</surname>
                  </persName>
                  <idno type="halauthorid">384512-0</idno>
                  <affiliation ref="#struct-524560"/>
                </author>
              </analytic>
              <monogr>
                <idno type="halJournalId" status="VALID">4620</idno>
                <idno type="issn">0360-5442</idno>
                <idno type="eissn">1873-6785</idno>
                <title level="j">Energy</title>
                <imprint>
                  <publisher>Elsevier</publisher>
                  <biblScope unit="volume">91</biblScope>
                  <biblScope unit="pp">20-34</biblScope>
                  <date type="datePub">2015-11</date>
                </imprint>
              </monogr>
              <idno type="doi">10.1016/j.energy.2015.08.009</idno>
            </biblStruct>
          </sourceDesc>
          <profileDesc>
            <langUsage>
              <language ident="en">English</language>
            </langUsage>
            <textClass>
              <keywords scheme="author">
                <term xml:lang="en">Soft constraints</term>
                <term xml:lang="en">Fault Tolerant Control (FTC)</term>
                <term xml:lang="en">Mixed-Integer Linear Programming (MILP)</term>
                <term xml:lang="en">Model Predictive Control (MPC)</term>
                <term xml:lang="en">Uncertainty</term>
                <term xml:lang="en">Microgrid energy management</term>
              </keywords>
              <classCode scheme="halDomain" n="spi.nrj">Engineering Sciences [physics]/Electric power</classCode>
              <classCode scheme="halTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halOldTypology" n="ART">Journal articles</classCode>
              <classCode scheme="halTreeTypology" n="ART">Journal articles</classCode>
            </textClass>
            <abstract xml:lang="en">
              <p>This paper presents an extension of a Model Predictive Control (MPC) approach for microgrid energy management which takes into account electricity costs, power consumption , generation profiles, power and energy constraints as well as uncertainty due to variations in the environment. The approach is based on a coherent framework of control tools, like mixed-integer programming and soft constrained MPC, for describing the microgrid components dynamics and the overall system control architecture. Fault tolerant strategies are inserted in order to ensure the proper amount of energy in the storage devices such that (together with the utility grid) the essential consumer demand is always covered. Simulation results on a particular microgrid architecture validate the proposed approach.</p>
            </abstract>
          </profileDesc>
        </biblFull>
      </listBibl>
    </body>
    <back>
      <listOrg type="structures">
        <org type="laboratory" xml:id="struct-25697" status="OLD">
          <orgName>Laboratoire de Conception et d'Intégration des Systèmes</orgName>
          <orgName type="acronym">LCIS</orgName>
          <date type="start">1996-01-01</date>
          <date type="end">2015-12-31</date>
          <desc>
            <address>
              <addrLine>50, rue Barthélémy de Laffemas – BP54 26902 Valence Cedex 9</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://lcis.inpg.fr</ref>
          </desc>
          <listRelation>
            <relation active="#struct-3886" type="direct"/>
            <relation active="#struct-300275" type="direct"/>
          </listRelation>
        </org>
        <org type="laboratory" xml:id="struct-161195" status="OLD">
          <orgName>Chaire Sciences des Systèmes et Défis Energétiques EDF/ECP/Supélec</orgName>
          <orgName type="acronym">SSEC</orgName>
          <date type="end">2019-12-31</date>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
          <listRelation>
            <relation active="#struct-303397" type="direct"/>
            <relation active="#struct-411575" type="direct"/>
            <relation active="#struct-528389" type="direct"/>
            <relation active="#struct-302313" type="indirect"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-524560" status="VALID">
          <idno type="IdRef">067072089</idno>
          <idno type="ISNI">000000012109901X</idno>
          <idno type="ROR">https://ror.org/0558j5q12</idno>
          <idno type="Wikidata">Q1465448</idno>
          <orgName>Polytechnic University of Bucharest [Romania] = Université Politehnica de Bucarest [Roumanie] = Universitatea Națională de Știință și Tehnologie Politehnica București [România]</orgName>
          <orgName type="acronym">UPB</orgName>
          <date type="start">1818-01-01</date>
          <desc>
            <address>
              <addrLine>Splaiul Independenței nr. 313, Sector 6, București, România, cod poștal RO-060042</addrLine>
              <country key="RO"/>
            </address>
            <ref type="url">https://upb.ro/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-3886" status="OLD">
          <idno type="IdRef">02640432X</idno>
          <idno type="ROR">https://ror.org/02f7wz369</idno>
          <orgName>Université Pierre Mendès France - Grenoble 2</orgName>
          <orgName type="acronym">UPMF</orgName>
          <date type="end">2015-12-31</date>
          <desc>
            <address>
              <addrLine>BP 47 - 38040 Grenoble Cedex 9</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.upmf-grenoble.fr/</ref>
          </desc>
        </org>
        <org type="institution" xml:id="struct-300275" status="OLD">
          <idno type="IdRef">026388804</idno>
          <orgName>Institut National Polytechnique de Grenoble</orgName>
          <orgName type="acronym">INPG</orgName>
          <date type="end">2006-12-31</date>
          <desc>
            <address>
              <addrLine>46 avenue Félix Viallet 38031 Grenoble Cedex 1</addrLine>
              <country key="FR"/>
            </address>
          </desc>
        </org>
        <org type="institution" xml:id="struct-303397" status="VALID">
          <orgName>Ecole Supérieure d'Electricité - SUPELEC (FRANCE)</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
          </desc>
        </org>
        <org type="institution" xml:id="struct-411575" status="VALID">
          <idno type="IdRef">184443237</idno>
          <idno type="ROR">https://ror.org/019tcpt25</idno>
          <orgName>CentraleSupélec</orgName>
          <desc>
            <address>
              <addrLine>3, rue Joliot Curie,Plateau de Moulon,91192 GIF-SUR-YVETTE Cedex</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">http://www.centralesupelec.fr</ref>
          </desc>
        </org>
        <org type="regrouplaboratory" xml:id="struct-528389" status="VALID">
          <orgName>EDF R&amp;D</orgName>
          <orgName type="acronym">EDF R&amp;D</orgName>
          <desc>
            <address>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.edf.fr/groupe-edf/qui-sommes-nous/activites/recherche-et-developpement</ref>
          </desc>
          <listRelation>
            <relation active="#struct-302313" type="direct"/>
          </listRelation>
        </org>
        <org type="institution" xml:id="struct-302313" status="VALID">
          <idno type="IdRef">026436965</idno>
          <idno type="ISNI">0000000122985443</idno>
          <idno type="ROR">https://ror.org/03wb8xz10</idno>
          <idno type="Wikidata">Q274591</idno>
          <orgName>EDF – Électricité de France</orgName>
          <orgName type="acronym">EDF [E.D.F.]</orgName>
          <date type="start">1946-04-08</date>
          <desc>
            <address>
              <addrLine>22-30 – 22 avenue de Wagram – 75008 Paris – France</addrLine>
              <country key="FR"/>
            </address>
            <ref type="url">https://www.edf.fr/</ref>
          </desc>
        </org>
      </listOrg>
    </back>
  </text>
</TEI>