Actuator fault detection and isolation for diesel engines - Archive ouverte HAL Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Actuator fault detection and isolation for diesel engines

Résumé

This work addresses the issues of actu- ator fault detection and isolation for diesel engines. We are particularly interested to diagnosis faults af- fecting the Exhaust Gas Recirculation (EGR) and the variable Nozzle Turbine (VNT) actuator valves. To accomplish this goal, a residual generator based on a nonlinear mean value model of the diesel engine is proposed using a bank of observer. Each residual on the proposed scheme is based on a nonlinear unknown input observer and designed to be insensitive to only one fault. By using this kind of scheme, the actuator faults can be easily isolated since only one residual goes to zero while the others do not. A decision al- gorithm based on multi-CUSUM is used. The perfor- mances of the proposed approach are shown through the application to a diesel engine model.
Fichier non déposé

Dates et versions

hal-00822583 , version 1 (15-05-2013)

Identifiants

  • HAL Id : hal-00822583 , version 1

Citer

Boulaïd Boulkroune, Abdel Aitouche, Vincent Cocquempot. Actuator fault detection and isolation for diesel engines. 2013 IEEE Multi-Conference on Systems and Control (MSC 2013, Aug 2013, Hyderabad, India. pp.1-6. ⟨hal-00822583⟩
262 Consultations