Bacterial and fungal counts in hospital air: comparative yields for 4 sieve impactor air samplers with 2 culture media. - Archive ouverte HAL
Article Dans Une Revue Infection Control and Hospital Epidemiology Année : 2006

Bacterial and fungal counts in hospital air: comparative yields for 4 sieve impactor air samplers with 2 culture media.

Résumé

We compared the yields of 4 recently developed sieve impactor air samplers that meet international standard ISO 14698-1, using 2 growth media (tryptic soy agar and malt extract agar) in real conditions of use. Several hospital sites expected to have different densities of airborne microflora were selected in 2 hospitals. The Samplair MK2, Air Ideal, and Mas-100 samplers yielded higher bacterial counts than did the SAS Super-100 device (P<.05). No significant differences in fungal counts were noted between the 4 devices. The use of malt extract agar in addition to tryptic soy agar significantly improved the fungal yield.
Fichier non déposé

Dates et versions

hal-00700065 , version 1 (22-05-2012)

Identifiants

Citer

Jean-Pierre Gangneux, Florence Robert-Gangneux, Guirec Gicquel, Jean-Jacques Tanquerel, Sylviane Chevrier, et al.. Bacterial and fungal counts in hospital air: comparative yields for 4 sieve impactor air samplers with 2 culture media.. Infection Control and Hospital Epidemiology, 2006, 27 (12), pp.1405-8. ⟨10.1086/508840⟩. ⟨hal-00700065⟩
74 Consultations
0 Téléchargements

Altmetric

Partager

More