A Self-paced Hybrid BCI based on EEG and EOG
Résumé
Daily-used BCIs should provide users the freedom to realize the control through all possible physiological functions and to turn on/off the control system independently. Thus, we propose a hybrid BCI (hBCI) that combines ocular-based control with a self-paced on/off brain switch. The proposed system involves the detection of α-rhythm in EEG and ocular activities in EOG data. Experiments carried out on four subjects illustrate the interest of the proposed method.
Origine | Fichiers produits par l'(les) auteur(s) |
---|