A Long Stroke Electromagnetic XY Positioning Stage for Micro Applications - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue IEEE/ASME Transactions on Mechatronics Année : 2011

A Long Stroke Electromagnetic XY Positioning Stage for Micro Applications

Muneeb Ullah Khan
Nabil Bencheikh
  • Fonction : Auteur
Christine Prelle
Frédéric Lamarque
  • Fonction : Auteur

Résumé

In this paper, a Lorentz force-based XY positioning stage with a stack of four electromagnetic linear motors in parallel configuration is presented. The overall design of the positioning stage consists of a mobile and a fixed part separated using a four-point contact technique. The uniqueness of the proposed positioning stage lies in its light design with the ability to perform variable strokes at short (<100 μm) and long range (millimeter level) with preembedded auto guidance feature. The analytical modeling and experiment have been realized. The open- and closed-loop performance of positioning stage in linear and nonlinear trajectories have been tested and good agreement is observed between experimental and analytical results. The positioning stage is able to perform variable strokes up till 2 mm in the xy plane. In closed loop, the maximum precision errors in short and long strokes are found to be 0.031 and 0.451 μm, respectively. The maximum travel speed is 12 mm/s in open loop.
Fichier principal
Vignette du fichier
A_Long_Stroke_Electromagnetic_XY_Positioning.pdf (1.29 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-00593755 , version 1 (17-05-2011)

Identifiants

Citer

Muneeb Ullah Khan, Nabil Bencheikh, Christine Prelle, Frédéric Lamarque, Tobias Beutel, et al.. A Long Stroke Electromagnetic XY Positioning Stage for Micro Applications. IEEE/ASME Transactions on Mechatronics, 2011, pp.1-10. ⟨10.1109/TMECH.2011.2142319⟩. ⟨hal-00593755⟩
103 Consultations
732 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More