Fully Distributed Initialization Procedure for a 2D-Mesh NoC, Including Off Line BIST and Partial Deactivation of Faulty Components - Archive ouverte HAL
Communication Dans Un Congrès Année : 2010

Fully Distributed Initialization Procedure for a 2D-Mesh NoC, Including Off Line BIST and Partial Deactivation of Faulty Components

Résumé

In this paper, we present an embedded, at speed, off-line, and fully distributed initialization procedure for 2D-Mesh Network-on-Chip (NoC). This procedure is executed at power boot, and targets the detection and the deactivation of the faulty routers and/or faulty communication channels. The final objective is fault tolerance. The proposed procedure is able to clean the NoC from all destructive malfunctions induced by permanent hardware failures. This initialization procedure has been implemented in a reconfigurable version of the DSPIN micro-network, and evaluated from the point of view of Stuck-at fault coverage, and area overhead.
Fichier principal
Vignette du fichier
article.pdf (214.35 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00591795 , version 1 (10-05-2011)

Identifiants

Citer

Zhen Zhang, Alain Greiner, Mounir Benabdenbi. Fully Distributed Initialization Procedure for a 2D-Mesh NoC, Including Off Line BIST and Partial Deactivation of Faulty Components. The 16th IEEE International On-Line Testing Symposium (IOLTS), Jun 2010, Corfu, Greece. pp.194-196, ⟨10.1109/IOLTS.2010.5560209⟩. ⟨hal-00591795⟩
313 Consultations
354 Téléchargements

Altmetric

Partager

More