Impact of the Physical Layout of High-Current Rectifiers on Current Division and Magnetic Field Using PEEC Method

Résumé

This paper addresses some problems linked to the physical layout of high-current rectifiers: paralleling components, magnetic field close to the rectifier, and also the validation of the physical layout at reduced current. Even if the impact of cabling stray inductance is well known, some new tools and methodology are available today to design quicker and safer physical layout of such high-current rectifiers.
Fichier principal
Vignette du fichier
05404300.pdf (1.48 Mo) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-00578211 , version 1 (18-03-2011)

Identifiants

Citer

Jean-Luc Schanen, Jean-Michel Guichon, James Roudet, Cyril Domenech, Luc Meysenc. Impact of the Physical Layout of High-Current Rectifiers on Current Division and Magnetic Field Using PEEC Method. IEEE Transactions on Industry Applications, 2010, 46 (2), pp892-900. ⟨10.1109/tia.2010.2041083⟩. ⟨hal-00578211⟩