Abstract

In this paper, The difference between getting the output spectrum directly using spectrum analyzer and obtaining the spectrum digitally in measuring clock jitter effect on continuous-time ΣΔ modulator is analyzed. It is shown that clock jitter can be seen as input-referred or output-referred, depending on the nature of the measurement tool. Quantization noise and jitter noise are analyzed and compared graphically using a simple approach. The presented analysis is verified with system-level simulation of a 4th order bandpass continuous-time ΣΔ modulator.

Domains

Electronics
No file

Dates and versions

hal-00574516 , version 1 (08-03-2011)

Identifiers

Cite

Ahmed Ashry, Ahmed K. El-Shennawy, Mohammad Elbadry, Ayman Elsayed, Hassan Aboushady. Measurement of continuous-time ΣΔ modulators: Implications of using spectrum analyzer. IEEE International Conference on Microelectronics (ICM'10), Dec 2010, Cairo, Egypt. pp.9-12, ⟨10.1109/ICM.2010.5696216⟩. ⟨hal-00574516⟩