Accurate Transient Behavior Measurement of High- Voltage ESD Protections Based on a Very Fast Transmission-Line Pulse System - Archive ouverte HAL
Communication Dans Un Congrès Année : 2009

Accurate Transient Behavior Measurement of High- Voltage ESD Protections Based on a Very Fast Transmission-Line Pulse System

Résumé

A comprehensive study of the limitations of vf-TLP setup for transient measurements is exposed. A new method, based on a numerical correction of measured data using a commercial Oryx vf-TLP system is presented. It allows the measurement of ESD pulses up to 1000 V with a time resolution down to 60 ps.
Fichier principal
Vignette du fichier
Delmas-eosesd09.pdf (325.02 Ko) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-00445676 , version 1 (11-01-2010)

Identifiants

  • HAL Id : hal-00445676 , version 1

Citer

Antoine Delmas, Nicolas Nolhier, David Trémouilles, Marise Bafleur, Nicolas Mauran, et al.. Accurate Transient Behavior Measurement of High- Voltage ESD Protections Based on a Very Fast Transmission-Line Pulse System. 31st Electrical Overstress/Electrostatic Discharge Symposium, 2009. EOS/ESD Symposium, Aug 2009, ANAHEIM, United States. pp.165-172. ⟨hal-00445676⟩